A Retrospective Study Using the String of Pearls Tibial Plateau Levelling Osteotomy Locking Plate for the Treatment of Cranial Cruciate Ligament Disease

Author:

McGregor Ross E.1,Buffa Eugene A.1,Tan Christopher J.2,Schembri Mark A.3,Badcock Caro-Anne4,Lai Alen5

Affiliation:

1. Northside Veterinary Specialists, Sydney, Australia

2. Sydney Veterinary Emergency and Specialists, Sydney, Australia

3. Post Graduate Foundation in Veterinary Science, The University of Sydney, Sydney, Australia

4. Shimsco Consulting, Wootton, Australia

5. Northshore Veterinary Specialist Centre, Sydney, Australia

Abstract

Objective The aim of this study was to describe the use of String of Pearls (SOP) tibial plateau levelling osteotomy (TPLO) locking plates for the treatment of cranial cruciate ligament disease and retrospectively assess osteotomy healing, tibial plateau angle (TPA) change (c) and overall complication rates. Methods Medical records and radiographic studies of 170 SOP TPLO surgical procedures were analysed. Radiographic measurement of TPAc and osteotomy union was determined 6 to 8 weeks postoperatively. Intra- and postoperative major and minor complications were identified. Factors influencing TPAc, osteotomy union and complications were assessed. Results Mean (standard deviation) TPAc was 1.3° (1.61) and median osteotomy union was graded as 2 (26–50%) union. Improved osteotomy union was associated with retention of the antirotational pin (odds ratio [OR]: 2.3; 95% confidence interval [CI]: 1.3–4; p = 0.005) and reduced TPAc (OR: 0.8; 95%CI: 0.66–0.97; p = 0.02). Complications occurred in 42 (24.7%) procedures with 11 (6.5%) considered major and 31 (18.2%) minor. Clinical significance The use of the SOP TPLO plating system resulted in a median grade 2 (26–50%) radiographic osteotomy union score at 6 to 8 weeks' follow-up, less than previous TPLO locking plate studies. Osteotomy union was associated with retention of the antirotational pin and reduced TPAc. Major and minor complication rates were marginally greater than recent locking plate studies with fibular fracture and screw loosening common complications. The use of SOP TPLO plates is cautioned and further study is warranted.

Publisher

Georg Thieme Verlag KG

Subject

General Veterinary,Animal Science and Zoology

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3