Cartridge-Based Thromboelastography Can Be Used to Monitor and Quantify the Activity of Unfractionated and Low-Molecular-Weight Heparins

Author:

Dias João D.1,Lopez-Espina Carlos G.2,Panigada Mauro3,Dalton Heidi J.4,Hartmann Jan5,Achneck Hardean E.5

Affiliation:

1. Haemonetics Corporation, Signy, Switzerland

2. Haemonetics Corporation, Rosemont, Illinois, United States

3. Fondazione IRCCS Ca' Granda - Ospedale Maggiore Policlinico, Milan, Italy

4. Department of Pediatrics, Inova Health and Vascular Institute, Falls Church, Virginia, United States

5. Haemonetics Corporation, Braintree, Massachusetts, United States

Abstract

AbstractThromboelastography is increasingly utilized in the management of bleeding and thrombotic complications where heparin management remains a cornerstone. This study assessed the feasibility of the cartridge-based TEG® 6s system (Haemonetics Corp., Braintree, Massachusetts, United States) to monitor and quantify the effect of unfractionated and low-molecular-weight heparin (UFH and LMWH). Blood samples from healthy donors were spiked with UFH (n = 23; 0–1.0 IU/mL) or LMWH (enoxaparin; n = 22; 0–1.5 IU/mL). Functional fibrinogen maximum amplitude (CFF.MA), RapidTEG activated clotting time (CRT.ACT), and kaolin and kaolin with heparinase reaction time (CK.R and CKH.R) were evaluated for their correlation with heparin concentrations, as well as the combination parameters ΔCK.R − CKH.R, ratio CK.R/CKH.R, and ratio CKH.R/CK.R. Nonlinear mixed-effect modelling was used to study the relationship between concentrations and parameters, and Bayesian classification modelling for the prediction of therapeutic ranges. CK.R and CRT.ACT strongly correlated with the activity of LMWH and UFH (p < 0.001). Using combination parameters, heparin activity could be accurately quantified in the range of 0.05 to 0.8 IU/mL for UFH and 0.1 to 1.5 IU/mL for LMWH. CRT.ACT was able to quantify heparin activity at higher concentrations but was only different from the reference range (p < 0.05) at >0.5 IU/mL for UFH and >1.5 IU/mL for LMWH. Combination parameters classified blood samples into subtherapeutic, therapeutic, and supratherapeutic heparin ranges, with an accuracy of >90% for UFH, and >78% for LMWH. This study suggests that TEG 6s can effectively monitor and quantify heparin activity for LMWH and UFH. Additionally, combination parameters can be used to classify blood samples into therapeutic ranges based on heparin activity.

Publisher

Georg Thieme Verlag KG

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3