Rapid Centrifugation in the Routine Hemostasis Laboratory

Author:

Wolfensberger Nathan1,Georgiou Georgios2,Giabbani Evelyne3,Reusser Marianne3,Njue Linet M.3,Fiedler Martin4,Leichtle Alexander B.45,Nagler Michael34

Affiliation:

1. Department of Medical Oncology and Hematology, University Hospital Zurich, Zurich, Switzerland

2. Unilabs Lausanne, Lausanne, Switzerland

3. Department of Hematology and Central Hematology Laboratory, Inselspital, Bern University Hospital, University of Bern, Bern, Switzerland

4. University Institute of Clinical Chemistry, Inselspital, Bern University Hospital, University of Bern, Bern, Switzerland

5. Insel Data Science Center, Inselspital, Bern University Hospital, University of Bern, Bern, Switzerland

Abstract

Abstract Background The use of short and uniform centrifugation schemes contributes significantly to the successful automation of laboratory procedures. It is however unclear if this is applicable to the hemostasis laboratory. Objectives This article assesses the accuracy of measurements obtained with a rapid, high-speed centrifugation scheme in a large set of hemostasis tests, covering the full spectrum of values obtained in clinical practice, and using meaningful statistical measures. Methods Two citrated plasma samples were obtained from consecutive patients of a tertiary hospital with suspected abnormal hemostasis tests and processed with two centrifugation schemes in parallel: 1,500 × g for 10 minutes and 3,137 × g for 7 minutes. The following tests were conducted: prothrombin time (n = 125), international normalized ratio (n = 146), activated partial thromboplastin time (n = 119), thrombin time (n = 105), fibrinogen (n = 125), factor (F)II (n = 69), FV (n = 64), FVII (n = 64), FX (n = 67), FVIII (n = 55), FIX (n = 37), FXI (n = 35), and FXIII (n = 20), D-dimer (n = 34), antithrombin (n = 31), anti-Xa activity (n = 30), von Willebrand antigen (n = 25), and von Willebrand activity (VWF:GPIbM; n = 27). Results A wide range of results were obtained in all tests. Spearman's rank correlation coefficient was at least 0.95 for all tests except FV, FIX, and FXI. The coverage probability π at a given deviation index κ of 15% was above 0.9 for all tests except FV, FVII, FX, FVIII, FIX, FXI, and VWF:GPIbM, suggesting a lack of agreement. Conclusion Our results suggest that high-speed centrifugation is applicable to the majority of routine hemostasis parameters. The coverage probability was more sensitive than Spearman's rank correlation to detect disagreement among centrifugation schemes.

Publisher

Georg Thieme Verlag KG

Subject

Hematology

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3