A Comparative Study of Orotracheal Intubation Guided by Airtraq and McCoy Laryngoscope in Patients with Rigid Cervical Collar In-situ Simulating Cervical Immobilization for Traumatic Cervical Spine Injury

Author:

Diwan Akhil1,Purohit Shobha1

Affiliation:

1. Department of Anesthesia, SMS Hospital, Jaipur, Rajasthan, India

Abstract

Abstract Background Immobilization of cervical spine is of utmost importance in patients with cervical injury, making intubation a difficult task due to the application of cervical collar. This study was done to assess which laryngoscope (Airtraq or McCoy) is better for intubation and prevents the deleterious effects of hypoxia by comparing the intubation time. Methods A prospective interventional randomized study was undertaken in 60 adult patients of American Society of Anesthesiologists (ASA) grade I and II, aged between 20 and 50 years, scheduled for various surgical procedures requiring tracheal intubation for anesthesia. Patients were randomly allocated to undergo intubation with either the Airtraq (Group A; n = 30) laryngoscope or McCoy (Group B; n = 30). Patients were intubated following the standard anesthetic protocol, and the differences in duration of intubation, changes in the hemodynamic parameters in response to intubation, modified intubation difficulty score, and airway complications between the Airtraq and the McCoy laryngoscope were compared. Results Overall intubation success rates were 100% with both devices and a similar number of intubation attempts were required. Though the mean time required for successful intubation was less with the Airtraq (25.2 ± 5.11 seconds) than the McCoy laryngoscope (27.3 ± 4.47 seconds); it was statistically insignificant (p = 0.14). Intubation difficulty score and ease of insertion were significantly less in Airtraq laryngoscope when compared with McCoy laryngoscope. Increase in the heart rate and mean arterial pressure was significantly more just after intubation with McCoy in comparison with Airtraq laryngoscope. However, the frequencies of airway complications were similar. Conclusion Intubation time despite being lesser with the Airtraq than the McCoy laryngoscope was statistically insignificant, and overall success rates between the two devices were similar.

Publisher

Georg Thieme Verlag KG

Subject

Materials Chemistry

Cited by 2 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3