Vein Size Mismatch Increases Flap Failure in Lower Extremity Trauma Free Flap Reconstruction

Author:

Lee Z-Hye1,Alfonso Allyson R.1,Stranix John T.1,Anzai Lavinia1,Daar David A.1,Ceradini Daniel J.1,Levine Jamie P.1,Saadeh Pierre B.1,Thanik Vishal1

Affiliation:

1. Hansjörg Wyss Department of Plastic Surgery, NYU Langone Health, New York, United States

Abstract

Abstract Background Venous outflow problems are the most common reasons for perioperative flap complications. Size mismatch in venous anastomoses poses a theoretical problem by promoting turbulent flow and subsequent thrombus formation. The purpose of this study was to determine if increased vein size mismatch is predictive of flap failure. Methods Retrospective review of our institutional flap registry from 1979 to 2016 identified 410 free flaps performed for reconstruction of lower extremity trauma. Patient demographics, flap characteristics, and flap outcomes were examined. Venous size mismatch was defined as a difference in size ≥ 1 mm between the recipient vein and flap vein. Results Vein size mismatch ≥ 1mm was present in 17.1% (n = 70) of patients. The majority of anastomoses were end-to-end (n = 379, 92.4%), and end-to-side anastomoses were preferentially used in the presence of vein size mismatch (p < 0.001). Major complications occurred in 119 (29%) flaps, with 35 (8.5%) partial flap losses and 34 (8.3%) total flap losses. Looking specifically at flaps with end-to-end venous anastomoses, venous size mismatch was associated with increased total flap failure (p = 0.031) and takeback for vascular compromise (p = 0.030). Recipient vein size relative to flap vein size (larger or smaller) had no effect on flap outcomes. Multivariable regression analysis controlling for age, sex, flap type, number of veins, recipient vein size, flap vein size, venous coupler use, and vein size mismatch demonstrated that flaps with ≥ 1 mm vein mismatch were predictive of total flap failure (p = 0.045; odds ratio: 2.58). Conclusion Flaps with vein size mismatch ≥ 1 mm demonstrated increased flap complication rates in the setting of end-to-end venous anastomoses. End-to-side anastomosis was preferentially used in vein size mismatch and carried a higher risk of flap failure. Our results support using veins of similar size for anastomosis whenever feasible to protect against flap complications.

Publisher

Georg Thieme Verlag KG

Subject

Surgery

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3