Detection of Global Brain Injury Using Point-of-Care Neonatal MRI Scanner

Author:

Bin-Nun Alona12,Kasirer Yair1,Abu-Ata Nadeen3,Rosenbaum Debra1,Cytter-Kuint Ruth2,Hammerman Cathy12ORCID,Ben-David Eliel23

Affiliation:

1. Department of Neonatology, Shaare Zedek Medical Center, Jerusalem, Israel

2. The Faculty of Medicine, the Hebrew University, Campus Ein Kerem, Jerusalem, Israel

3. Department of Radiology, Shaare Zedek Medical Center, Jerusalem, Israel

Abstract

Abstract Background Conventional magnetic resonance imaging (MRI) neuroimaging of infants is complicated by the need to transport infants outside the neonatal intensive care unit (NICU), often to distant areas of the hospital. Primary Objective The main aim of this study was to evaluate and compare scoring of images from a novel 1T MRI, which enables neuroimaging within the NICU, with those from a conventional MRI. Secondary Objective The second aim of this study was to document improved expediency, and thereby greater patient safety, as reflected by decreased transport time. Materials and Methods Thirty premature infants (mean gestational age: 28.8 ± 2.1 weeks) were scanned consecutively on the novel 1T and 1.5T conventional scanners at term-equivalent age. Orthogonal T1- and T2-weighted images were acquired and reviewed. A global brain abnormality score (Kidokoro) was assigned independently to all images by two radiologists. Interrater agreement was evaluated using the kappa statistic and interscanner agreement was evaluated by Bland–Altman analysis. Transport time to and from both scanners was monitored and compared. Results Weighted kappas were 0.77 (standard error of measurement [SEM] 0.08; confidence interval [CI]: 0.62–0.92) and 0.86 (SEM: 0.07; CI: 0.73–1), for the 1T and 1.5T scanners, respectively, reflecting substantial interrater agreement. Bland–Altman analysis showed excellent agreement between the two scanners.Transport time was 8 ± 6 minutes for the 1T MRI versus 46 ± 21 minutes for the conventional MRI (p < 0.00001). No adverse events were recorded during transport. Standard transport times will vary from institution to institution. Conclusions Kidokoro scores are similar when comparing images obtained from a 1T MRI with those of a conventional 1.5T MRI, reflecting comparable image quality. Transport time was significantly decreased using the 1T neonatal MRI.

Publisher

Georg Thieme Verlag KG

Subject

Neurology (clinical),General Medicine,Pediatrics, Perinatology and Child Health

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司