Radiographic Outcomes following K-Wire Augmentation of Dorsal Spanning Plate Fixation for Intra-Articular Fractures of the Distal Radius

Author:

Shah Harsh A.1,Martin Anthony R.1,Geller Joseph S.1,Iyer Hariharan1,Dodds Seth D.1ORCID

Affiliation:

1. Department of Orthopaedics, University of Miami, Miller School of Medicine, Miami, Florida

Abstract

Abstract Background Restoration of articular surface alignment is critical in treating intra-articular distal radius fractures. Dorsal spanning plate fixation functions as an internal distraction mechanism and can be advantageous in the setting of highly comminuted fracture patterns, polytrauma patients, and patients with radiocarpal instability. The addition of K-wires to support articular surface reduction potentially augments fracture repair stability. Questions/Purposes We examined the radiographic outcomes and maintenance of reduction in patients with comminuted intra-articular distal radius fractures treated with K-wire fixation of articular fragments followed by dorsal spanning plate application. Patients and Methods We reviewed 35 consecutive patients with complex intra-articular distal radius fractures treated with dorsal spanning plate and K-wire fixation between April 2016 and October 2019. AO classification was recorded: B1 (3), B3 (2), C2 (2), C3 (28). A two-tailed paired t-test was used to compare findings immediately post-dorsal spanning plate surgery and at final follow-up after dorsal spanning plate removal. Results Mean patient age was 43.3 years (19–78 years). Mean follow-up was 7.8 months (SD 4.3 months) from surgery and 2.5 months from pin removal (SD 2.6 months). All patients achieved radiographic union. Radial height (mean interval change (MIC) 0.2 mm, SD 2.2, p = 0.63), articular step-off (MIC 0.1 mm, SD 0.6 mm, p = 0.88), and radial inclination (MIC −1.1 degrees, SD 3.7 degrees, p = 0.10) did not change from post-surgery to final follow-up. Ulnar variance (MIC −0.9 mm, SD 2.0 mm, p = 0.02) and volar tilt (MIC −1.5 degrees, SD 4.4 degrees, p = 0.05) were found to have decreased. Conclusion Dorsal spanning plate augmented with K-wire fixation for comminuted intra-articular distal radius fractures in polytrauma patients allows for immediate weightbearing and maintains articular surface alignment at radiographic union and may provide better articular restoration than treatment with dorsal spanning plate alone. Level of Evidence This is a Level IV, therapeutic study.

Publisher

Georg Thieme Verlag KG

Subject

Orthopedics and Sports Medicine,Surgery

Cited by 2 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3