Abstract

Abstract Background In recent years, new arthroscopic techniques have been introduced to address the irreparable tears of the triangular fibrocartilage complex (TFCC) (Palmer type 1B, Atzei class 4) by replicating the standard Adams–Berger procedure. These techniques, however, show the same limitations of the open procedure in relation to the anatomically defective location of the radial origins of the radioulnar ligaments (RUL) and the risk of neurovascular and/or tendon injury. Aiming to improve the quality of reconstruction and reduce surgical morbidity, a novel arthroscopic technique was developed, with the advantages of reproducing the anatomical origins of the RUL ligaments and providing all-inside tendon graft (TG) deployment and fixation. Description of Technique The Allinside anatomic arthroscopic (3A) technique is indicated for TG reconstruction of irreparable TFCC tears in the absence of distal radioulnar joint (DRUJ) arthritis. Standard wrist arthroscopy portals are used. A small incision in the radial metaphyseal area and arthroscopic control are required to set a Wrist Drill Guide and create two converging tunnels, whose openings are at the radial anatomical origins of the RUL. An ulnar tunnel is drilled at the fovea from inside-out via the 6U portal. A 3-mm tendon strip, from the palmaris longus or extensor carpi radialis brevis, is woven through the tunnels and then secured into the ulnar tunnel with an interference screw. Postoperative immobilization with restricted forearm rotation is discontinued at 5 weeks, and then postoperative rehabilitation is started. Patients and Methods The 3A technique was applied on 5 patients (2 females and 3 males), with an average age 42 years. DRUJ stability, range of motion (ROM), pain (0–10 visual analogue scale [VAS]), grip strength, modified Mayo wrist score (MMWS), and patient satisfaction were used for evaluation before surgery and at follow-up. Results No intraoperative or early complications were registered. At a mean follow-up of 26 months, DRUJ was stable in all patients, which recovered 99% ROM. Pain VAS decreased from 7 to 0.6. Grip strength increased from 38 to 48.8 Kgs. There were 4 excellent results and 1 good result on MMWS. All patient showed high satisfaction. Conclusions Although the 3A technique requires dedicated instrumentation and arthroscopic expertise, it takes advantage of improved intra-articular vision and minimized surgical trauma to reduce the risk of complications and obtain promising functional results.

Publisher

Georg Thieme Verlag KG

Subject

Orthopedics and Sports Medicine,Surgery

Cited by 3 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

1. Complications after arthroscopic triangular fibrocartilage complex (TFCC) surgery;Journal of Hand Surgery (European Volume);2024-02

2. All-Arthroscopic Foveal Triangular Fibrocartilage Complex Tendon Reconstruction;Journal of Wrist Surgery;2022-07-06

3. Revolutions in arthroscopic wrist surgeries;Journal of Hand Surgery (European Volume);2021-07-22

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3