Onsite Computed Tomography Fractional Flow Reserve in Patients with Suspected Stable Coronary Artery Disease Initial Experience

Author:

Kapoor Atul1,Mahajan Goldaa1,Kapoor Aprajita1

Affiliation:

1. Department of Computed Tomography, Advanced Diagnostics and Institute of Imaging, Amritsar, Punjab, India

Abstract

Abstract Introduction Computed tomographic coronary angiographic (CTCA) has evolved into a robust technique to detect significant stenosis; however, there is a discordance in the anatomic and functional significance of stenosis. Therefore, patients with stable coronary artery disease need to be further evaluated before deciding for any revascularization procedure. Material and Methods A total of 100 consecutive patients of suspected stable coronary artery disease who underwent CTCA were evaluated for functional significance of lesions using onsite computed tomography fractional flow reserve (CTFFR) and the results were compared for detection of both significant and hemodynamically significant/severe stenosis on per vessel and per patient basis and differences were statistically analyzed. Impact of these differences were analyzed for the final outcome and management plan. Results CTCA detected 33 patients with severe stenosis, while 54 patients had hemodynamically significant stenosis on CTFFR. The sensitivity and specificity of CTCA for the detection of significant coronary artery stenosis per vessel basis were 97.7 and 93.3%, respectively, with a negative predictive value of 98.0%. For severe coronary artery stenosis, sensitivity, specificity, and negative and positive predictive values were 51.6, 89, 68.8, and 80%, respectively, on per vessel basis with CTCA. On per patient basis, CTCA showed as sensitivity and specificity of 61 and 84%, respectively, with area under curve (AUC) being 0.92 and 0.67 for significant and severe stenosis, respectively. Discussion Onsite CTFFR is a useful tool to calculate functionally significant stenosis and also improves the sensitivity and specificity of CTCA. CTFFR detected 12% more stenotic vessels in the present study on per vessel basis and 21% on per patient basis.

Publisher

Georg Thieme Verlag KG

Subject

Radiology Nuclear Medicine and imaging

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3