A Wireless Near-Infrared Spectroscopy Device for Flap Monitoring: Proof of Concept in a Porcine Musculocutaneous Flap Model

Author:

Wu Changsheng1,Rwei Alina Y.12,Lee Jong Yoon13ORCID,Ouyang Wei1,Jacobson Lauren4,Shen Haixu5,Luan Haiwen1,Xu Yameng6,Park Jun Bin3,Kwak Sung Soo1,Ni Xiaoyue1,Bai Wubin5,Franklin Daniel1,Li Shuo1,Liu Yiming7,Ni Xinchen1,Westman Amanda M.4,MacEwan Matthew R.6,Rogers John A.15789,Pet Mitchell A.4ORCID

Affiliation:

1. Department of Materials Science and Engineering, Querrey Simpson Institute for Bioelectronics, Northwestern University, Chicago, Illinois

2. Department of Chemical Engineering, Delft University of Technology, Delft, The Netherlands

3. Sibel Inc., Evanston, Illinois

4. Division of Plastic and Reconstructive Surgery, Department of Surgery, School of Medicine, Washington University, St. Louis, Missouri

5. Department of Materials Science and Engineering, Northwestern University, Evanston, Illinois

6. Department of Neurosurgery, School of Medicine, Washington University, St. Louis, Missouri

7. Department of Electrical and Computer Engineering, Northwestern University, Evanston, Illinois

8. Department of Mechanical Engineering, Northwestern University, Evanston, Illinois

9. Department of Biomedical Engineering, Northwestern University, Evanston, Illinois

Abstract

Abstract Background Current near-infrared spectroscopy (NIRS)-based systems for continuous flap monitoring are highly sensitive for detecting malperfusion. However, the clinical utility and user experience are limited by the wired connection between the sensor and bedside console. This wire leads to instability of the flap–sensor interface and may cause false alarms. Methods We present a novel wearable wireless NIRS sensor for continuous fasciocutaneous free flap monitoring. This waterproof silicone-encapsulated Bluetooth-enabled device contains two light-emitting diodes and two photodetectors in addition to a battery sufficient for 5 days of uninterrupted function. This novel device was compared with a ViOptix T.Ox monitor in a porcine rectus abdominus myocutaneous flap model of arterial and venous occlusions. Results Devices were tested in four flaps using three animals. Both devices produced very similar tissue oxygen saturation (StO2) tracings throughout the vascular clamping events, with obvious and parallel changes occurring on arterial clamping, arterial release, venous clamping, and venous release. Small interdevice variations in absolute StO2 value readings and magnitude of change were observed. The normalized cross-correlation at zero lag describing correspondence between the novel NIRS and T.Ox devices was >0.99 in each trial. Conclusion The wireless NIRS flap monitor is capable of detecting StO2 changes resultant from arterial vascular occlusive events. In this porcine flap model, the functionality of this novel sensor closely mirrored that of the T.Ox wired platform. This device is waterproof, highly adhesive, skin conforming, and has sufficient battery life to function for 5 days. Clinical testing is necessary to determine if this wireless functionality translates into fewer false-positive alarms and a better user experience.

Funder

Division of Plastic Surgery and the Department of Neurosurgery at Washington University

Querry Simpson Institute of Bioelectronics at Northwestern University

Publisher

Georg Thieme Verlag KG

Subject

Surgery

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3