Evaluation of the MANTA Vascular Closure Device in Transfemoral TAVI

Author:

Kmiec Lukasz1ORCID,Zerdzitzki Matthaeus1,Schmid Christof1,Debl Kurt2,Sossalla Samuel2,Hilker Michael1,Holzamer Andreas1

Affiliation:

1. Department of Cardiothoracic Surgery, University Medical Center Regensburg, Regensburg, Germany

2. Department of Internal Medicine II, University Medical Center Regensburg, Regensburg, Germany

Abstract

Abstract Background The MANTA vascular closure device (VCD) is a novel collagen plug-based VCD for large bore arteriotomies. The current literature regarding complication rates of this device is quite variable and mostly limited to relatively small case series. Methods This study is retrospective analysis of the MANTA VCD-related main access site complications according to Valve Academic Research Consortium-2 (VARC-2) criteria during the hospital stay. Particular attention was paid to the detailed analysis of multislice computed tomography with regard to the anatomy of the access vessel and the puncture site itself. Results A total of 524 patients underwent transfemoral transcatheter aortic valve implantation (TF TAVI) including the use of the MANTA device (18F) for percutaneous vascular closure. A group of 22 patients was excluded from the study due to incomplete imaging data. During the study period, we observed 28 major (5.6%) and five minor (1.0%) MANTA device-related vascular complications. There was no patient death related to these adverse events. Female gender, vessel angulation at the puncture site, and at least moderate calcification of the dorsal vessel segment were identified as independent predictors for major complications. Conclusions The MANTA device is a feasible option for vascular closure of large bore arteriotomies in patients undergoing TF TAVI or other percutaneous transfemoral interventions. Furthermore, we have identified novel predictors for device failure/complications that should be taken into account for selection of the appropriate closure device. To our knowledge, this report is one of the largest case series analyzing the use of the MANTA VCD.

Publisher

Georg Thieme Verlag KG

Subject

Cardiology and Cardiovascular Medicine,Pulmonary and Respiratory Medicine,Surgery

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3