Sensor Use in Cruciate-Retaining Total Knee Arthroplasty Compared with Posterior-Stabilized Total Knee Arthroplasty: Load Balancing and Posterior Femoral Rollback

Author:

Song Sang Jun1,Kim Kang Il1,Park Cheol Hee1ORCID

Affiliation:

1. Department of Orthopaedic Surgery, College of Medicine, Kyung Hee University, Seoul, Korea

Abstract

AbstractThe purpose was to investigate the proportion of severe load imbalance after appropriate conventional gap balancing and analyze the intraoperative kinematics after load balancing in cruciate-retaining (CR) and posterior-stabilized (PS) total knee arthroplasties (TKAs). In total, 45 sensor-assisted CR and 45 PS TKAs using NexGen prosthesis were prospectively evaluated. After appropriate conventional gap balancing, the loads at 10, 45, and 90 degrees of knee flexion were evaluated with a wireless load sensor placed in trial implants. The proportion of severe load imbalance (medial load–lateral load >75 lbs) was investigated. After load balancing, location of the femorotibial contact point was investigated at each flexion angle to analyze femorotibial kinematics. The proportion of the severe load imbalance was significantly higher in CR TKAs at the 10 degrees knee flexion (37.8 vs. 15.6%, p = 0.031). This proportion was higher in CR TKAs than in PS TKAs at the 45 and 90 degrees knee flexion angles, but without statistical significance (31.1 vs. 15.6%, p = 0.134 and 33.3 vs. 15.6%, p = 0.085, respectively). After load balancing, consistent posterior femoral rollback occurred in medial and lateral compartments during 90 degrees flexion in CR TKAs (p < 0.001), but not in PS TKAs. Medial pivot kinematics was not observed in both TKA designs. The sensor was more beneficial in CR TKAs for achieving appropriate load balancing and consistent posterior femoral rollback compared with PS TKAs. Further studies are required to identify target load distribution to restore ideal knee kinematics after TKA. This study shows level of evidence II.

Publisher

Georg Thieme Verlag KG

Subject

Orthopedics and Sports Medicine,Surgery

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

1. The application of impantable sensors in the musculoskeletal system: a review;Frontiers in Bioengineering and Biotechnology;2024-01-24

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3