Comparison of Dosimetric Parameters of Three- Dimensional Conformal Radiotherapy and Intensity- Modulated Radiotherapy in Breast Cancer Patients Undergoing Adjuvant Radiotherapy after Modified Radical Mastectomy

Author:

Mehta Ankita1,Kumar Piyush1,Silambarasan N.S.1,Kumar Arvind1,Kumar Pavan1

Affiliation:

1. Department of Radiation Oncology, Shri Ram Murti Smarak Institute of Medical Sciences, Bareilly, Uttar Pradesh, India

Abstract

Abstract Introduction Adjuvant radiotherapy has an important role in preventing locoregional recurrences. But radiation-induced late sequelae have become an important area of concern. The ideal postmastectomy radiotherapy technique is an area of controversy. The present study was designed to compare two widely practiced conformal techniques, three-dimensional conformal radiotherapy (3DCRT) and intensity-modulated radiotherapy (IMRT), in terms of dosimetry. Material and Methods A total of 50 postmodified radical mastectomy patients were selected and were randomized to treatment either by 3DCRT or IMRT technique. Two opposing tangential beams were used in 3DCRT plans whereas five to seven tangential beams were used for IMRT plans. The prescribed dose was 50 Gy in 25 fractions over 5 weeks. The dosimetric parameters were compared for planning target volume (PTV), lungs, heart, and left ventricle, opposite breast and esophagus. Results The dosimetric parameters of PTV in terms of D95%, D90%, D50%, and Dmean showed no significant difference among both techniques. The IMRT technique had significantly better mean values of Dnear-min/D98% (45.56 vs. 37.92 Gy; p = 0.01) and Dnear-max/D2% (51.47 vs. 53.65 Gy; p < 0.001). Also, conformity index (1.07 vs. 1.29; p = 0.004) and homogeneity index (0.22 vs. 0.46; p = 0.003) were significantly better in IMRT arm.The dosimetric parameters of ipsilateral lung were significantly higher in IMRT arm in terms of mean dose (19.92 vs. 14.69 Gy; p < 0.001) and low/medium dose regions (V5, V10, V13, V15, V20; p < 0.05). However, high-dose regions (V40) were significantly higher in 3DCRT arm (15.57 vs. 19.89 Gy; p = 0.02). In contralateral lung also, mean dose was significantly higher in IMRT technique (3.63 vs. 0.53 Gy; p < 0.0001) along with low-dose regions (V5, V10, V13, V15; p < 0.05) while V20 was comparable between both the arms.In left-sided patients, the heart dose favored 3DCRT technique in terms of mean dose (17.33 vs. 8.51 Gy; p = 0.003), low/medium dose regions (V5, V10, V20; p < 0.05), and doses to partial/whole volumes (D33, D67, D100). But the high-dose regions (V25, V30, V40) were comparable between both the arms. The dosimetry of left ventricle also showed significantly lesser values of mean dose and V5 in 3DCRT technique (p < 0.0001).The opposite breast also showed higher mean dose with IMRT technique (2.60 vs. 1.47 Gy; p = 0.009) along with higher V5 (11.60 vs. 3.83 Gy; p = 0.001). The dosimetric parameters of esophagus showed higher mean dose in IMRT technique (10.04 vs. 3.24 Gy; p < 0.0001) but the high-dose regions V35 and V50 were comparable between both the arms. Conclusion A clear advantage could not be demonstrated with any of the techniques. The IMRT technique led to more conformal and homogenous dose distribution with reduction in high-dose regions in ipsilateral lung while the 3DCRT technique showed lesser mean dose to organs at risk (OARs). The exposure of large volumes of OARs to low doses in IMRT technique may translate to increased long-term radiation-induced complications. The shortcomings of 3DCRT technique can be overcome by using multiple subfields within tangential fields.

Publisher

Georg Thieme Verlag KG

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3