A Descriptive Analysis of Capsule Endoscopy Events in the FDA Manufacturer and User Facility Device Experience (MAUDE) Database

Author:

Ji Hangyu1,Wang Shaoli1,Gong Yang2

Affiliation:

1. China Academy of Chinese Medical Sciences Guang’anmen Hospital, Beijing, People’s Republic of China

2. School of Biomedical Informatics, University of Texas Health Science Center at Houston, Texas, United States

Abstract

Abstract Introduction The malfunction of capsule endoscopy (CE) devices is a significant reason for the failure of CE procedures, which could hinder and prevent diagnosis. Unfortunately, malfunction-related adverse events (AEs) caused by CE devices are rarely reported in publications. Although most malfunction-related AEs could not lead to physical harm, they could reduce the efficiency of medical care and increase medical costs. The manufacturer and user facility device experience (MAUDE) database, a publicly accessible resource for patient safety, contains not only the common complications of CE but also valuable malfunction-related AEs, which have been underutilized. Therefore, the study aims to discover and analyze the possible AEs associated with CE and demonstrate the utility of the MAUDE reports to promote patient safety. Materials and Methods We acquired MAUDE reports of CE systems from January 01, 2008, to July 31, 2020, through a systematic search strategy. We utilized the manufacturers, brand names, and product codes as search terms from which medical device reports including structured data and narrative texts were extracted, followed by a manual review of the narrative texts, reporter occupation, device involved, event type and the phase of the event; finally, patient outcomes were recorded and analyzed as per CE categories and characteristics. Results A total of 377 CEs medical device reports were retrieved, and 342 reports were included after reviewing. There were 327 mandatory reports (96%) and 15 voluntary reports (4%). These reports referred to capsule endoscope (n = 213), sensing system (n = 66), patency capsule (n = 38), and capsule delivery device (n = 26). A total of 349 CE-related AEs were identified, including complications (n = 228), malfunction-related AEs (n = 109), and other events (n = 12). The composition of AEs was not the same for the CE devices. Complications were major AEs of capsule endoscope and patency capsule, but malfunction-related AEs were the most common in AEs of sensing systems and capsule delivery devices. Conclusion MAUDE serves as an invaluable data source for investigating malfunction-related AEs. In addition to common complications, malfunction of CE devices could threaten patient safety in CE procedures. Improving awareness of the malfunction of CE devices and raising adequate training for staff working in gastrointestinal (GI) endoscopic units could be critical and beneficial in preventing malfunction-related AEs.

Publisher

Georg Thieme Verlag KG

Subject

Gastroenterology,Radiology Nuclear Medicine and imaging

Cited by 2 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3