Penetration and Tensile Strength of Various Impression Materials of Vinylsiloxanether, Polyether, and Polyvinylsiloxane Impression Materials

Author:

Apinsathanon Pongsakorn1ORCID,Bhattarai Bishwa Prakash2ORCID,Suphangul Suphachai3ORCID,Wongsirichat Natthamet2ORCID,Aimjirakul Napapa1ORCID

Affiliation:

1. Department of Conservative Dentistry and Prosthodontics, Faculty of Dentistry, Srinakharinwirot University, Bangkok, Thailand

2. Walailak University International College of Dentistry, Phaya Thai, Bangkok, Thailand

3. Department of Advanced General Dentistry, Faculty of Dentistry, Mahidol University, Bangkok, Thailand

Abstract

Abstract Objectives The aim of this study was to evaluate and compare penetration ability and tensile strength among vinylsiloxanether (VSE), polyether (PE), and polyvinylsiloxane (PVS) elastomeric dental impression materials. Materials and Methods The models were constructed for penetration ability test by simulated gingival sulcus width and moist environment. The 0.05, 0.1, and 0.2 mm of simulated gingival sulcus widths were used. Each simulated gingival sulcus width was impressed 10 repeats per one elastomeric impression material. All extension of elastomeric dental impression materials was scaled by Measuring Microscope (MM-11; Nikon, Tokyo, Japan). On the issue of the tensile strength study, the models were constructed following type 1 of the ISO 37:2017 specifications and/or type C of ASTM.D412 specifications. The two-way analysis of variance (ANOVA) and Tukey's honest significant difference test were performed in the penetration ability test. The one-way ANOVA and Dunnett's T3 test were performed in the tensile strength test. The significance level was set at 0.05. Results PE showed the best extension into all widths of simulated sulcus followed by VSE and PVS, respectively. PVS was significantly higher in tensile strength than VSE and PE, while VSE was significantly higher than PE. Conclusion Penetration ability of elastomeric dental impression materials was depended on gingival sulcus width. The wider the sulcular width, the better the penetration ability of elastomeric dental impression materials. PE presented the best penetration ability, while the novel PVS showed highest tensile strength.

Funder

Srinakharinwirot University, Bangkok, Thailand

Publisher

Georg Thieme Verlag KG

Subject

General Dentistry

Cited by 2 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司