Early Aseptic Loosening with Increased Presence and Severity of Backside Burnishing in the Optetrak Logic Posterior-Stabilized Total Knee Arthroplasty Femoral Component

Author:

Malahias Michael-Alexander1,Iacobelli David A.2,Torres Lisa3,Rojas Marcos Carolena1,Nocon Allina A.1,Wright Timothy M.3,Sculco Peter K.1,Sculco Thomas P.1

Affiliation:

1. The Stavros Niarchos Foundation Complex Joint Reconstruction Center, Hospital for Special Surgery, New York City, New York

2. Adult Reconstruction and Joint Replacement, Hospital for Special Surgery, New York City, New York

3. Department of Biomechanics, Hospital for Special Surgery, New York City, New York

Abstract

AbstractConcerns persist that the Optetrak Logic posterior-stabilized (PS) total knee arthroplasty (TKA) femoral component might correlate with early failures due to aseptic loosening. The primary aim of this study was to examine if the use of the Optetrak Logic PS femoral component is associated with early (<5 years) and more extensive aseptic loosening compared with other PS femoral components. This is a single-institution retrieval analysis and revision registry study (based on prospectively collected data) of 27 failed primary PS TKA patients with loose femoral components that underwent revision TKAs between 2016 and 2019. Patients were stratified by components type: Group A (n = 16) received the Optetrak Logic PS femoral component, while Group B (n = 11) received other PS femoral components. Burnishing (macroscopic polishing of the component's backside) was observed and graded as a marker for relative motion at the cement-implant interface. No significant differences were found between the two groups regarding the baseline demographic, radiographic, and clinical characteristics. Mean length of implantation for Group A (3.8 ± 2.9 years) was significantly shorter (p < 0.001) than that of Group B (12.0 ± 6.7 years). A significant difference (p = 0.009) was found in presence of backside femoral burnishing between Group A (15 of 16 patients; 93.8%) and group B (5 of 11 patients; 45.6%). Furthermore, we found a significant difference (p < 0.001) in the severity of burnishing between Group A (13 of 16 patients with severe degree of burnishing; 81.3%) and Group B (1 of 11 patients with severe degree of burnishing; 9.1%). In contrast to Group B, a distinctive macroscopic pattern found in Logic retrieved femoral components (Group A) was the total absence of cement in the backside surface. The use of the Optetrak Logic PS TKA femoral component was associated with early aseptic loosening and increased presence and severity of backside burnishing with early cement-implant interface debonding compared with other commercially available types of PS TKA femoral components. The earlier failure rate with this implant is of concern.

Publisher

Georg Thieme Verlag KG

Subject

Orthopedics and Sports Medicine,Surgery

Reference15 articles.

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3