Abstract

Abstract Background Magnetic resonance imaging (MRI) is the imaging modality of choice for evaluating perianal fistulae, due to its ability to show the relationship of perianal fistulae with anal sphincters, fistula extensions, secondary ramifications and associated complications. Aim To evaluate the role of diffusion-weighted MRI in the evaluation of perianal fistulae. Settings and Design A hospital-based cross-sectional study. Materials and Methods The study group composed of 47 patients of perianal fistula. MRI with diffusion-weighted imaging (DWI) was performed with Philips 0.5 T Ingenia scanner. DWI with different b-values (b = 50, b = 400, and b = 800 smm2) were obtained. The MRI findings were correlated with local clinical examination and or surgical findings. Statistical Analysis Used Chi-square test, independent samples t-test, and receiver operating characteristic curve analysis. Result Fifty-nine perianal fistulas in 47 patients were included in the study sample. The visibility of perianal fistula on DWI was less than T2-weighted (T2W) and combined DWI-T2W images. Distinctly visualized (visibility score 2) perianal fistulas were observed in 47 fistulas (79.6%) on DWI, 54 (91.5%) on T2W, and 58 (98.3%) on DWI-T2W images. The mean of apparent diffusion coefficient (ADC) values of active fistula was 0.972 ± 0.127 [SD] 10−3 mm2/s and inactive was 1.232 ± 0.185 [SD] 10−3 mm2/s with a significant difference (p-value < 0.0005). A cut-off mean ADC value of 1.105 × 10−3 mm2/s was used to differentiate active from the inactive fistula with a sensitivity of 87.5% and specificity of 73.3%. Conclusion Combined DWI-T2W evaluation had a better performance in the detection of fistula than DWI or T2W alone. DWI with mean ADC calculation had a good performance in differentiating active from the inactive fistulas.

Publisher

Georg Thieme Verlag KG

Subject

Radiology Nuclear Medicine and imaging

Reference22 articles.

1. An assessment of the incidence of fistula-in-ano in four countries of the European Union;C Zanotti;Int J Colorectal Dis,2007

2. 3D-EAUS and MRI in the activity of anal fistulas in Crohn’s disease;M E Alabiso;Gastroenterol Res Pract,2016

3. MR imaging evaluation of perianal fistulas: spectrum of imaging features;J de Miguel Criado;Radiographics,2012

4. MRI in evaluation of perianal fistula;U George;J Med Imaging Radiat Oncol,2011

5. Imaging of fistula in ano;S Halligan;Radiology,2006

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3