Kirschner Wire Fixation in Dorsally Displaced Distal Radius Fractures: A Biomechanical Evaluation

Author:

Sanders Liam1,Johnson Nick1ORCID,Dias Joseph J.1

Affiliation:

1. Department of Trauma and Orthopaedics, Academic Team of Musculoskeletal Surgery, University Hospitals of Leicester, Leicester General Hospital, Leicester, United Kingdom

Abstract

Abstract Background There is currently no consensus for the optimum configuration and number of Kirschner wires (K-wires) to use for the stabilization of dorsally displaced distal radius fractures. In this biomechanical study, we compared the load to failure and stiffness of four common K-wire configurations to identify the strongest construct for use in extra-articular dorsally displaced distal radius fractures. Case Description We created a standard distal radius fracture model in turkey tarsometatarsi which was stabilized using two or three K-wires (1.6 mm) in four different configurations. Following a power calculation, 10 fracture models of each configuration underwent testing in cantilever bending and axial compression. Literature Review Recent randomized trials have shown no evidence that volar locking plates are superior to K-wires for the treatment of dorsally displaced distal radius fractures. This has led to an increase in the popularity of much cheaper K-wires. Several different K-wire techniques have been described but there is no strong evidence to determine which is the optimal configuration and number of wires. Clinical Relevance The three-wire interfragmentary configuration was stiffer than the three-wire Kapandji in axial compression and cantilever bending. There was no difference in load to failure in cantilever bending or axial compression. The three-wire interfragmentary technique is the stiffest configuration of K-wires for dorsally displaced distal radius fractures. The two-wire Kapandji technique was significantly weaker than the other configurations, especially in cantilever bending. Conclusion The authors recommend to always use three wires for percutaneous pinning and never to use two intrafocal wires alone.

Publisher

Georg Thieme Verlag KG

Subject

Orthopedics and Sports Medicine,Surgery

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

1. Distal Radius K-Wiring Failed Fracture Fixation;Failed Fracture Fixation;2024

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3