The Effect of Nonlinear Frequency Compression on Acoustic Change Complex Responses in High-Frequency Dead-Regioned Hearing Loss

Author:

Kösemihal Ebru1,Akdas Ferda2

Affiliation:

1. Department of Audiology, Near East University, Nicosia, Cyprus

2. Department of Audiology, Marmara University School of Medicine, Istanbul, Turkey

Abstract

Abstract Purpose The study is concern with the distinguishing of the stimuli containing high frequency information with the frequency compression feature at the cortical level using the acoustic change complex (ACC) and the comparison of such with the ACC answers of individuals with normal hearing. Research Design This is a case–control study. Study Sample Thirty adults (21 males and nine females) with normal hearing, ranging in age between 16 and 63 years (mean: 36.7 ± 12.9 years) and 20 adults (16 males and four females) with hearing loss ranging in age between 16 and 70 years (mean:49.0 ± 19.8 years) have been included in this study. Data Collection and Analysis A total of 1,000 ms long stimulus containing 500 and 4,000 Hz tonal stimuli was used for ACC recording. The start frequency (SF) and compression ratio (CR) parameters of the hearing aids were programmed according to the default settings (SFd, CRd) in the device software, the optimal setting (SFo, CRo), and the extra compression (SFe, CRe) requirements and ACC has been recorded for each condition. Evaluation has been performed according to P1-N1-P2 wave complex and ACC complex wave latencies. Independent samples t-test was used to test the significance of the differences between the groups. Results In all individuals ACC has been observed. There was a significant difference between the wave latencies in normal hearing- and hearing-impaired groups. All wave latency averages of the individuals with hearing impairment were longer than the individuals with normal hearing. There were statistically significant differences between SFd-SFo, SFd-SFe, and SFo-SFe parameters. But there was no difference between CRd, CRo, and CRe in terms of CRs. Conclusion In order to discriminate high frequency information at the cortical level we should not rely on default settings of the SF and CR of the hearing aids. Optimal bandwidth must be adjusted without performing insufficient compression or over-compression. ACC can be used besides the real ear measurement for hearing aid fitting.

Publisher

Georg Thieme Verlag KG

Subject

Speech and Hearing

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3