3D Ultrasound Evaluation of the Fetal Ear – Comparison of an xMatrix Probe with a Conventional Mechanical Probe

Author:

Bürkel Kai1,Krämer Ursula2,Möllers Mareike3,Falkenberg Maria3,Klockenbusch Walter3,Schmitz Ralf3

Affiliation:

1. Gemeinschaftspr., Frauenärztliche, Schwalmtal, Germany

2. Institut für Umweltmedizinische Forschung, University of Düsseldorf, Germany

3. Department of Obstetrics and Gynecology, University Hospital Münster, Germany

Abstract

Abstract Purpose New 3 D technologies like xMatrix probes promise superiority over conventional mechanical probes and may allow a more detailed and time-saving prenatal diagnosis. In a comparison study we evaluate fetal ears. The aim of our study was to compare the following aspects of both techniques: (1) ultrasound detail resolution, (2) raw data acquisition time (AT) and (3) influence of covariates. Materials and Methods 3 D raw data volumes of the fetal ear were collected with the V6 – 2 (V6) and with the xMatrix (X6) probe and were stored after offline customization to a single picture. Two observers scored these images independently. Furthermore, the 3 D raw data acquisition time (AT) was recorded. Concordance between observers, maternal age, body mass index (BMI), weeks of gestation and location of the placenta were evaluated. Results Data volumes of 103 patients were analyzed. The X6 detected anatomic structures like the scapha (p = 0.0146), fossa triangularis (p = 0.0075) and cymba conchae (p = 0.0025) more often. The mean AT of the X6 was shorter compared to the V6 (p < 0.0001). A placenta location in the scanning field increased the AT only for the V6 (p < 0.01). Concordance between observers was higher for the X6 in most cases. Detailed structures were less visible at the end of pregnancy for both devices. Conclusion The comparison study demonstrated clear advantages of the new xMatrix technology concerning an advanced and fast examination of detailed structures like the fetal ear. The importance of 3 D assessment in cases of fetal ear anomaly should be proven in further studies.

Publisher

Georg Thieme Verlag KG

Subject

Radiology, Nuclear Medicine and imaging

Cited by 3 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3