Biomechanical Analysis of Ideal Knee Flexion Angle for ACL Graft Tensioning Utilizing Multiple Femoral and Tibial Tunnel Locations

Author:

Hammarstedt Jon E.1ORCID,Guth J. Jared1,Schimoler Patrick J.1,Kharlamov Alexander1,Miller Mark C.1,Akhavan Sam1,Demeo Patrick J.

Affiliation:

1. Department of Orthopaedic Surgery, Allegheny Health Network, Pittsburgh, Pennsylvania

Abstract

AbstractAnterior cruciate ligament (ACL) graft failure rate has been reported to be greater than 5% at 5 years. Our study evaluated ACL excursion with anatomic and nonanatomic femoral and tibial tunnels to determine optimal flexion angle to tension the ACL to minimize excursion. Ten cadaveric knee specimens were used. The ACL was sectioned and the femoral and tibial attachments were marked. A 1/16-inch drill created a tunnel in the center of the ACL footprint on the tibia and femur and additional tunnels were made 5 mm from this. A suture was passed through each tunnel combination and attached to a string potentiometer. The knee was ranged from full extension to 120 degrees of flexion for 10 cycles while mounted in a custom fixture. The change in length (excursion) of the suture during movement was recorded for each combination of femoral and tibial tunnels. Anatomic reconstruction of the ACL with tunnel placement in the center of the femoral and tibial footprint did not result in an isometric graft, with excursion of the ACL during knee motion of 7.46 mm (standard deviation [SD]: 2.7mm), greatest at 2.84 degrees of flexion (SD: 4.22). The tunnel combination that resulted in the least excursion was a femoral footprint 5 mm anterior to the femoral and 5 mm posterior to the tibial footprint (4. 2mm, SD: 1.37 mm). The tunnel combination that resulted in the most excursion utilized femoral footprint 5 mm proximal to the femoral and 5 mm posterior to the tibial footprint (9.81 mm, SD: 2.68 mm). Anatomic ACL reconstruction results in significant excursion of the ACL throughout motion. If not tensioned properly, the ACL can stretch during range of motion, potentially leading to rerupture. To prevent stretching of the graft, the current biomechanical study recommends tensioning an anatomic ACL reconstruction at its point of maximal excursion, or between 0 and 5 degrees of flexion. Level of Evidence IV

Publisher

Georg Thieme Verlag KG

Subject

Orthopedics and Sports Medicine,Surgery

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3