Low Incidence of Prosthesis-Patient Mismatch Following Extremely Small Transcatheter Aortic Valve Replacement with 20-mm Sapien 3

Author:

Okajima Kazue12ORCID,Komatsu Ikki34,Seto Todd B.13

Affiliation:

1. Department of Cardiology, University of Hawaii, John A. Burns School of Medicine, Honolulu, Hawaii

2. Department of Cardiology, Texas Tech University Health Sciences Center El Paso, Paul L. Foster School of Medicine, El Paso, Texas

3. Department of Cardiology, Queens Medical Center, Honolulu, Hawaii

4. Department of Cardiology, Tokyo Medical University, Tokyo, Japan

Abstract

AbstractTranscatheter aortic valve replacement has been developed as an emerging technique to treat patients with aortic valve disease. However, safety and outcome data on extremely small transcatheter heart valves (THV) is limited. We aimed to assess hemodynamic profiles and clinical outcome of very small balloon expandable THVs with 20-mm Sapien 3 (SP3).We examined data for all patients who received third-generation SP3 THV at a single hospital. Complications and clinical outcomes were defined based on the VARC-2 criteria. Postoperative prosthesis-patient mismatch (PPM) was defined as indexed effective orifice area (EOA) < 0.85 cm2/m2. We compared clinical characteristics and outcome between patients with 20-mm (n = 21), 23-mm (n = 67), and 26- or 29-mm (n = 113) sized valves.The 20-mm group included significantly higher number of Asian and female populations with lower body surface area. The baseline CT annular area in the 20-mm group was 316.5 ± 24.9 mm2. There was no significant difference between groups in procedural mortality or early safety at 30 days. The higher procedural complication was observed in 20-mm group due to significant differences in minor vascular and bleeding complications. Despite higher post-THV gradients and smaller indexed EOA in 20-mm group, no PPM was observed in 20-mm group. The mortality at 30 days and 1 year in 20-mm group was 4.8% and 16.7%, respectively.The patients who received very small THVs with 20-mm SP3 did not result in PPM and experienced favorable early safety and midterm outcome in our cohort.

Publisher

Georg Thieme Verlag KG

Subject

Cardiology and Cardiovascular Medicine

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司