Cysto-Vaginoscopy of a 3D-Printed Cloaca Model: A Step toward Personalized Noninvasive Preoperative Assessment in Patients with Complex Anorectal Malformations

Author:

Krois Wilfried1ORCID,Schmölz Lukas1,Wagner Michael2,Gröpel Peter3,Unger Ewald4,Berger Angelika2,Metzelder Martin1,Reck Carlos Albert1

Affiliation:

1. Department of Pediatric Surgery, Medical University of Vienna, Vienna, Wien, Austria

2. Department of Pediatrics, Medical University of Vienna, Wien, Austria

3. Department of Sport Science, University of Vienna, Wien, Austria

4. Center for Medical Physics and Biomedical Engineering, Medical University of Vienna, Wien, Austria

Abstract

Abstract Introduction For the classification of the complexity of cloacal malformations and the decision on the operative approach, an exact anatomical assessment is mandatory. To benefit from using three-dimensional (3D)-printed models in preoperative planning and training, the practicability of these models should be guaranteed. The aim of this study was to evaluate the quality and feasibility of a real-size 3D-printed cloaca model for the purpose of cysto-vaginoscopic evaluation. Materials and Methods We performed a 3D reconstruction and printed a real-size, rubber-like 3D model of an infant pelvis with a cloacal malformation and asked invited pediatric surgeons and pediatric urologists to perform a cysto-vaginoscopy on the model and to complete a brief questionnaire to rate the quality and feasibility of the model and to indicate whether they would recommend the model for preoperative planning and training. Results Overall, 41 participants rated the model quality as good to very good (M = 3.28, standard deviation [SD] = 0.50, on a scale from 1 to 4). The model was rated as feasible for preoperative training (M = 4.10, SD = 0.75, on a scale from 1 to 5) and most participants (85.4%) would recommend the model for preoperative training. The cysto-vaginoscopy of the model was considered as a valid training tool for real-life cases and improved the confidence on the anatomy of a cloaca. Conclusion The results of our study indicate that patient-specific 3D-printed models might be a useful tool in the preoperative evaluation of complex anorectal malformations by simulation of cysto-vaginoscopy with an excellent view on anatomical structures to assess the whole spectrum of the individual cloacal malformation. Our model might be a valuable add-on tool for specialty training in pediatric colorectal surgery.

Publisher

Georg Thieme Verlag KG

Subject

Surgery,Pediatrics, Perinatology and Child Health

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3