Accuracy and Safety of Image-Guided Freehand Pin Placement in Canine Cadaveric Vertebrae

Author:

Samer Eva S.1ORCID,Forterre Franck2ORCID,Rathmann Justus M.K.3,Stein Veronika M.1,Precht Christina M.4,Guevar Julien1ORCID

Affiliation:

1. Department of Clinical Veterinary Medicine, Division of Clinical Neurology, Vetsuisse Faculty, University of Bern, Bern, Switzerland

2. Department of Clinical Veterinary Medicine, Division of Small Animal Surgery, Vetsuisse Faculty, University of Bern, Bern, Switzerland

3. Institute of Sociology, University of Zurich, Zurich, Switzerland

4. Department of Clinical Veterinary Medicine, Division of Clinical Radiology, Vetsuisse Faculty, University of Bern, Bern, Switzerland

Abstract

Abstract Objective The aim of this study was to validate an imaging technique for evaluation of spinal surgery accuracy and to establish accuracy and safety of freehand technique in the thoracolumbar spine of large breed dogs. Study Design After thoracolumbar spine computed tomography (CT), 26 drilling corridors were planned then drilled to receive 3.2 mm positive profile pins using a freehand technique. After pin removal, CT was repeated. All entry points, exit points and angles of the preoperative planned trajectories were compared with postoperative ones using an image registration and fusion technique by three observers. Corridor coordinates for entry and exit points were evaluated in three dimensions and angles were measured in one plane. Intraclass correlation coefficient (ICC) was used to establish the imaging technique reliability and descriptive statistics were used to report on the freehand technique accuracy. Safety was evaluated using a vertebral cortical breach grading scheme. Results Intraclass correlation coefficient for the entry points, exit points and angle were 0.79, 0.96 and 0.92 respectively. Mean deviations for the entry points, exit points and angle were 3.1 mm, 6.3 mm and 7.6 degrees respectively. Maximum deviations were 6.3 mm, 11.0 mm and 16.4 degrees. Most deviations were lateral and caudal. All corridors were judged as safe. Conclusion The imaging technique reliability was good to excellent to study spinal surgery accuracy. Implant deviations should be anticipated when planning stabilization surgery in large breed dogs using the freehand-guided technique.

Publisher

Georg Thieme Verlag KG

Subject

General Veterinary,Animal Science and Zoology

Reference29 articles.

1. Vertebral stabilization using positively threaded profile pins and polymethylmethacrylate, with or without laminectomy, for spinal canal stenosis and vertebral instability caused by congenital thoracic vertebral anomalies;T Aikawa;Vet Surg,2007

2. Spinal fixation in dogs using Steinmann pins and methylmethacrylate;C E Blass;Vet Surg,1984

3. Canine degenerative lumbosacral stenosis: prevalence, impact and management strategies;A Worth;Vet Med (Auckl),2019

4. Vertebral fracture and luxation in small animals;N D Jeffery;Vet Clin North Am Small Anim Pract,2010

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3