Abstract

Abstract Background A standard method and parameter study were performed for the contralateral suppression test. Purpose Our study aimed to determine the contralateral transient-evoked otoacoustic emission (TEOAE) suppression test method and stimulus–noise parameters that have a standard procedure and will enable the efferent system to be easily evaluated in clinics. Research Design: This study was conducted in two parts with two different groups of participants as a within-subjects design. In the first part, the signal-to-noise ratio at which maximum suppression obtained was investigated with 29 participants. In the second part, the optimal contralateral noise presentation method (in terms of noise-time or noise-sweep) was examined with 21 participants. Study Sample In the first part 29 young adults aged between 18 and 32 (23.03 ± 2.84), 20 females and 9 males, and in the second part 21 young adults aged between 19 and 34 years (mean age: 23.71 ± 3.48 years), 16 females and 5 males, participated in the second part. All participants had normal hearing. Data Collection and Analysis To obtain maximum OAE suppression, different parameters were tested with the Otodynamics ILO292-II OAE device at both parts of the study in a double-walled audiometric test booths. Multirepeated analysis of variance, pairwise comparison, Friedman test, and Wilcoxon signed-rank tests were used for statistical analysis. Results In the first part, maximum suppression was achieved at 65 dB peSPL (decibel peak-equivalent sound pressure level) TEOAE stimulus and 65 dB SPL broadband noise. In the second part, maximum suppression was obtained in noise-time method with 30 seconds “duration.” Conclusions To provide standardization in clinics, it can be recommended that the contralateral suppression of OAEs was measured at 65 dB peSPL TEOAE stimulus and 65 dB SPL broadband noise in the linear stimulation mode with Otodynamics ILO 292-II double-probe OAE device. To obtain maximum suppression, the noise-time method with 30 seconds duration can be used.

Publisher

Georg Thieme Verlag KG

Subject

Speech and Hearing

Reference18 articles.

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3