Tensile Strength of Nerve Bridging Models Using Collagen Nerve Conduits

Author:

Hattori Yusuke,Takeda Shinsuke1,Usami Takuya1ORCID,Shibata Ryutaro1,Takahashi Hiroshi1,Joyo Yuji2,Kawaguchi Yohei1,Okamoto Hideki1,Murakami Hideki1,Paholpak Permsak3,Ota Hideyuki4

Affiliation:

1. Department of Orthopedic Surgery, Nagoya City University Graduate School of Medical Science, Nagoya, Japan

2. Department of Orthopedic Surgery, Nagoya City University East Medical Center, Nagoya, Japan

3. Department of Orthopedics, Faculty of Medicine, Khon Kaen University, Khon Kaen, Thailand

4. Department of Orthopedic Surgery and Hand Surgery, Nagoya Ekisaikai Hospital, Nagoya, Japan

Abstract

Abstract Background In the treatment of peripheral nerve injuries with nerve defects, second-generation collagen-based conduits, such as Renerve® (Nipro, Osaka, Japan), have shown the potential for promoting nerve regeneration. However, there is concern related to the weak material properties. No previous studies have addressed the strength of the bridging model using collagen conduits. This study aimed to investigate the tensile strength and failure patterns in nerve defect models bridged with Renerve® conduits through biomechanical research. Methods Using fresh chicken sciatic nerves, we examined the maximum failure load of four groups: bridging models using Renerve® with one suture (group A), with two sutures (group B), with three sutures (group C), and end-to-end neurorrhaphy models with two sutures (group N). Each group had eight specimens. We also evaluated failure patterns of the specimens. Results Group N showed a significantly higher maximum failure load (0.96 ± 0.13 N) compared to groups A (0.23 ± 0.06 N, p < 0.0001), B (0.29 ± 0.05 N, p < 0.0001), and C (0.40 ± 0.10 N, p < 0.0001). Regarding failure patterns, all specimens in group A showed nerve-end dislocation from the conduit. Two specimens in group B and three specimens in group C failed due to circumferential cracks in the conduit. Six specimens in group B and five specimens in group C exhibited cutting out of sutures from the conduit. Conclusion This study suggests that the number of sutures in synthetic collagen nerve conduits has little effect on the maximum failure load. To take advantage of its biomaterial benefits, a period of postoperative range of motion restriction may be required.

Funder

Nipro Joint research

Publisher

Georg Thieme Verlag KG

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3