How Implementing a Quality Management System at the LIONS Eye Bank Saar-Lor-Lux, Trier/Western Palatinate from 2006 to 2016 Impacted the Rate and Reasons for Discarding Human Organ-Cultured Corneas

Author:

Laun Daniel1,Suffo Shady1ORCID,Kramp Kristina1,Bischoff Mona1,Huber Manuela1,Langenbucher Achim2,Seitz Berthold1ORCID

Affiliation:

1. Klinik für Augenheilkunde, Universitätsklinikum des Saarlandes und Medizinische Fakultät der Universität des Saarlandes, Homburg, Deutschland

2. Institut für Experimentelle Ophthalmologie, Universitätsklinikum des Saarlandes und Medizinische Fakultät der Universität des Saarlandes, Homburg/Saar, Deutschland

Abstract

Abstract Background The aim of this study was to explore how the implementation of the quality management system (QM; according to DIN EN ISO 9001 : 2008) at the LIONS Eye Bank impacted the rate and reasons for discarding donated corneas. The QM system was introduced in November 2010. Material and methods The rate of and reasons for discarding cornea tissues at the LIONS Eye Bank Saar-Lor-Lux,Trier/Western Palatinate from 2006 to 2016 were analysed retrospectively. 4,140 corneas from 2,084 donors were analysed. 1,640 corneas were processed before the QM system had been introduced and 2,500 corneas thereafter. Main reasons for discarding cornea tissues were endothelial quality, contamination of the medium and a positive conjunctival swab. The data was extracted from clinical files and data filing systems, entered into a Microsoft Access database and analysed statistically with SPSS. Outcome Following the implementation of a QM system, the discard rate decreased significantly from 50.1% to 39.7% (p < 0.0001). Prior to the implementation of the QM system, 493 (30.1%) cornea tissues had been discarded due to endothelial quality, while this figure improved significantly to 604 (24.2%) after the QM system had been implemented (p < 0.0001). Contamination was the reason for discarding tissue in 173 (10.5%) cases before implementation of the QM system, and in 124 (5.0%) cases thereafter (p < 0.0001). Positive conjunctival swab was the reason for discarding tissue in 10 (0.6%) cases before the QM system had been implemented, and in 53 (2.1%) cases thereafter (p < 0.0001). Conclusion Implementation of a QM system significantly reduced the rate of discarded donor tissue in the LIONS Eye Bank. Better management of contamination as a reason for discarding cornea tissues can be attributed to improved standards, protocols and training that are part of this QM system.

Publisher

Georg Thieme Verlag KG

Subject

Ophthalmology

Reference26 articles.

1. The founder of the first eye bank: R. Townley Paton, MD;D Paton;Refract Corneal Surg,1991

2. Spendergewebe für die Keratoplastik – Erfahrungsbericht aus der Hamburger Hornhautbank;M Böhnke;Klin Monbl Augenheilkd,1991

3. Leistungsbericht der Deutschen Hornhautbanken 2009;N Schrage;Ophthalmologe,2011

4. Split-Cornea-Transplantation – ein neues Konzept gegen Spendermangel;L M Heindl;Klin Monbl Augenheilkd,2012

5. [Corneal donation: Dilemma between growing demand and declining donor rate];F Schaub;Ophthalmologe,2016