Is There a Role for Cerebral Ultrasonography in Near-Term/Term Neonates Following Assisted Vaginal Delivery? A Prospective, Single-Center Study

Author:

Poryo Martin1,Zimmer Anika2,Hamza Amr3,Wagenpfeil Stefan4,Zemlin Michael5,Geipel Martina5,Löffler Günther5,Meyer Sascha56,Tutdibi Erol5

Affiliation:

1. Department of Pediatric Cardiology, Saarland University Medical Center and Saarland University Faculty of Medicine, Homburg, Germany

2. Medical School, Saarland University Medical Center and Saarland University Faculty of Medicine, Homburg, Germany

3. Department of Gynecology, Saarland University Medical Center and Saarland University Faculty of Medicine, Homburg, Germany

4. Institute for Medical Biometry, Epidemiology and Medical Informatics, Saarland University Medical Center and Saarland University Faculty of Medicine, Homburg, Germany

5. Department of Pediatrics and Neonatology, Universitatsklinikum des Saarlandes und Medizinische Fakultat der Universitat des Saarlandes, General Pediatrics and Neonatology, Germany

6. Department of Neuropediatrics, Saarland University Medical Center and Saarland University Faculty of Medicine, Homburg, Germany

Abstract

Abstract Aim To evaluate the role of cerebral ultrasonography studies (CUSS) in detecting intracerebral and cranial pathologies (hemorrhages, ischemia, skull fractures) in near-term and term neonates following assisted vaginal delivery. Patients and Methods Prospective single-center study (11/2017–11/2018) at the University Children’s Hospital of Saarland, Homburg, Germany including newborns with a gestational age ≥ 36 weeks born by assisted vaginal delivery. In all newborns, a standardized CUSS was performed within the first three days of life prior to discharge. Results 200 neonates (43.0 % female, 57.0 % male; gestational age 39.6 ± 1.3 weeks) were included in this study (birth weight 3345.6 ± 450.6 g, body length 51.7 ± 2.5 cm, head circumference 35.0 ± 1.5 cm). 67 (33.5 %) neonates had minor external injuries of the scalp. 5 children showed clinical neurologic abnormalities: 4 (2.0 %) seizures and 1 facial palsy (0.5 %). In 34 (17.0 %) patients, minor incidental intracranial abnormalities unrelated to mode of delivery were detected on CUSS. No intracerebral, cranial pathologies or skull fractures were seen on routine CUSS. Conclusion Routine CUSS in newborns after assisted vaginal delivery did not yield clinically relevant results in our cohort. Clinical observation and selective CUSS in symptomatic newborns might be more efficient than routine CUSS.

Publisher

Georg Thieme Verlag KG

Subject

Radiology Nuclear Medicine and imaging

Reference27 articles.

1. Instrumental Rotation for Persistent Fetal Occiput Posterior Position: A Way to Decrease Maternal and Neonatal Injury?;F Vidal;PLoS One,2013

2. Factors influencing the likelihood of instrumental delivery success;C E Aiken;Obstet Gynecol,2014

3. Trial of instrumental delivery in theatre versus immediate caesarean section for anticipated difficult assisted births;F Majoko;Cochrane database Syst Rev,2012

4. ACOG Practice Bulletin No. 154: Operative Vaginal Delivery;Committee on Practice Bulletins—Obstetrics;Obstet Gynecol,2015

5. Vacuum-assisted delivery: a review;R W McQuivey;J Matern Fetal Neonatal Med,2004

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3