Forward-viewing echoendoscope versus standard echoendoscope for endoscopic ultrasound-guided tissue acquisition of solid lesions: a randomized, multicenter study

Author:

Larghi Alberto1,Ibrahim Mostafa2,Fuccio Lorenzo3,Lekkerkerker Selma4,Eisendrath Pierre2,Frazzoni Leonardo3,Fockens Paul4,La Marca Marina3,van Hooft Jeanin E.4,Deviere Jacques2,Costamagna Guido156

Affiliation:

1. Digestive Endoscopy Unit, Fondazione Policlinico Universitario Agostino Gemelli, IRCCS, Rome, Italy

2. Department of Gastroenterology, Hepatopancreatology, and Digestive Oncology, Erasme University Hospital – Université Libre de Bruxelles, Brussels, Belgium

3. Department of Medical and Surgical Sciences, University of Bologna, Bologna, Italy

4. Department of Gastroenterology and Hepatology Academic Medical Center University of Amsterdam, Amsterdam, The Netherlands

5. Digestive Endoscopy Unit, Fondazione Policlinico Universitario Agostino Gemelli, Università Cattolica del Sacro Cuore, IRCCS, Rome, Italy

6. IHU-USIAS, University of Strasbourg, Strasbourg, France

Abstract

Abstract Background A forward-viewing linear (FVL) echoendoscope has been developed with the aim of overcoming some of the limitations of standard curved linear-array (CLA) echoendoscopes. There are no existing studies comparing the performance of the two echoendoscopes for endoscopic ultrasound-guided tissue acquisition (EUS-TA) of solid lesions other than subepithelial lesions. Methods This was a prospective, multicenter, randomized trial with a noninferiority design comparing FVL vs. CLA echoendoscopes in patients with solid lesions of the gastrointestinal tract or adjacent organs. Primary outcomes were successful identification of the lesion and success of EUS-TA. Secondary outcomes were safety, sensitivity, specificity, and diagnostic accuracy of the two different scopes for EUS-TA. Results 126 patients with solid lesions were randomly assigned to the CLA group (63 patients) or the FVL group (63 patients). The two groups were homogeneous with no differences in terms of needle type used, mean number of passes, and site of EUS-TA. No differences were observed between the FVL vs. CLA scopes in identification of the lesion (96.8 % vs. 98.4 %; P > 0.99) and technical success of EUS-TA (92.1 % vs. 96.8 %; P = 0.44). No adverse events occurred. Overall, diagnostic accuracy (77.8 % vs. 84.1 %), sensitivity (76.6 % vs. 84.1 %), and specificity (81.3 % vs. 84.2 %) did not differ between the two groups. Conclusions Our results strongly suggest that the FVL echoendoscope is noninferior to the CLA scope for the detection and performance of EUS-TA in patients with solid lesions of the gastrointestinal tract and adjacent organs. In addition, the FVL scope has the same diagnostic yield, accuracy, and safety as the CLA scope.

Publisher

Georg Thieme Verlag KG

Subject

Gastroenterology

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3