Safety and efficacy of lumen-apposing metal stents versus plastic stents to treat walled-off pancreatic necrosis: systematic review and meta-analysis

Author:

Chandrasekhara Vinay1,Barthet Marc2,Devière Jacques3,Bazerbachi Fateh4,Lakhtakia Sundeep5,Easler Jeffrey J.6,Peetermans Joyce A.7,McMullen Edmund7,Gjata Ornela7,Gourlay Margaret L.7,Abu Dayyeh Barham K.1

Affiliation:

1. Division of Gastroenterology and Hepatology, Mayo Clinic, Rochester, Minnesota, United States

2. Service d'hépato-gastroentérologie, Hôpital Nord, Chemin des Bourrely, Marseille, France

3. Université Libre de Bruxelles, Brussels, Belgium

4. Division of Gastroenterology, Interventional Endoscopy Program, Harvard Medical School and Massachusetts General Hospital, Boston, Massachusetts, United States

5. Gastroenterology and Therapeutic Endoscopy, Asian Institute of Gastroenterology, Hyderabad, India

6. Division of Gastroenterology and Hepatology, Indiana University School of Medicine, Indianapolis, United States

7. Endoscopy Division, Boston Scientific Corporation, Marlborough, Massachusetts, United States

Abstract

Abstract Background and study aims Lumen-apposing metal stents (LAMS) are increasingly used for drainage of walled-off pancreatic necrosis (WON). Recent studies suggested greater adverse event (AE) rates with LAMS for WON. We conducted a systematic review and meta-analysis to compare the safety and efficacy of LAMS with double-pigtail plastic stents (DPPS) for endoscopic drainage of WON. The primary aim was to evaluate stent-related AEs. Methods In October 2019, we searched the Ovid (Embase, MEDLINE, Cochrane) and Scopus databases for studies assessing a specific LAMS or DPPS for WON drainage conducted under EUS guidance. Safety outcomes were AE rates of bleeding, stent migration, perforation, and stent occlusion. Efficacy outcomes were WON resolution and number of procedures needed to achieve resolution. A subanalysis including non-EUS-guided cases was performed. Results Thirty studies including one randomized controlled trial (total 1,524 patients) were analyzed. LAMS were associated with similar bleeding (2.5 % vs. 4.6 %, P = 0.39) and perforation risk (0.5 % vs. 1.1 %, P = 0.35) compared to DPPS. WON resolution (87.4 % vs. 87.5 %, P = 0.99), number of procedures to achieve resolution (2.09 vs. 1.88, P = 0.72), stent migration (5.9 % vs. 6.8 %, P = 0.79), and stent occlusion (3.8 % vs. 5.2 %, P = 0.78) were similar for both groups. Inclusion of non-EUS-guided cases led to significantly higher DPPS bleeding and perforation rates. Conclusions LAMS and DPPS were associated with similar rates of AEs and WON resolution when limiting analysis to EUS-guided cases. Higher bleeding rates were seen in historical studies of DPPS without EUS guidance. Additional high-quality studies of WON treatment using consistent outcome definitions are needed.

Publisher

Georg Thieme Verlag KG

Subject

Gastroenterology,Medicine (miscellaneous)

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3