Tissue acquisition for diagnosis of biliary strictures using peroral cholangioscopy or endoscopic ultrasound-guided fine-needle aspiration

Author:

Lee Yun1,Moon Jong1,Choi Hyun1,Kim Hee2,Lee Hyun1,Lee Tae1,Choi Moon1,Cha Sang-Woo1,Cho Young1,Park Sang-Heum1

Affiliation:

1. Digestive Disease Center and Research Institute, Department of Internal Medicine, SoonChunHyang University School of Medicine, Bucheon and Seoul, Korea

2. Department of Pathology, SoonChunHyang University School of Medicine, Bucheon, Korea

Abstract

Abstract Background Although endoscopic retrograde cholangiopancreatography (ERCP) is a first-line diagnostic modality for suspected malignant biliary stricture (MBS), the diagnostic yield of ERCP-based tissue sampling is insufficient. Peroral cholangioscopy-guided forceps biopsy (POC-FB) and endoscopic ultrasound-guided fine-needle aspiration biopsy (EUS-FNAB) are evolving as reliable diagnostic procedures for inconclusive MBS. This study aimed to evaluate the usefulness of a diagnostic approach using POC-FB or EUS-FNAB according to the stricture location in patients with suspected MBS. Methods Consecutive patients diagnosed with suspected MBS with obstructive jaundice and/or cholangitis were enrolled prospectively. ERCP with transpapillary forceps biopsy (TPB) was performed initially. When malignancy was not confirmed by TPB, POC-FB using a SpyGlass direct visualization system or direct POC using an ultraslim endoscope was performed for proximal strictures, and EUS-FNAB was performed for distal strictures as a follow-up biopsy. Results Among a total of 181 patients, initial TPB showed malignancy in 122 patients, and the diagnostic accuracy of initial TPB was 71.8 % (95 % confidence interval [CI] 65.3 % – 78.4 %]. Of the 59 patients in whom TPB was negative for malignancy, 32 had proximal biliary strictures and underwent successful POC. The remaining 27 patients had distal strictures and underwent successful EUS-FNAB. The accuracy of malignancy detection using POC-FB for proximal biliary strictures and EUS-FNAB for distal biliary strictures was 93.6 % (95 %CI 84.9 %−100 %) and 96.3 % (95 %CI 89.2 %−100 %), respectively. The overall diagnostic accuracy for the combination of TPB with either POC-FB for proximal strictures and EUS-FNAB for distal strictures was 98.3 % (95 %CI 95.9 %−100 %) and 98.4 % (95 %CI 95.3 %−100 %), respectively. Conclusions An approach using POC-FB or EUS-FNAB according to the stricture location may be useful in the diagnosis of suspected MBS.

Publisher

Georg Thieme Verlag KG

Subject

Gastroenterology

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3