Preferred techniques for endoscopic ultrasound-guided gastroenterostomy: a survey of expert endosonographers

Author:

Magahis Patrick T.1ORCID,Salgado Sanjay2,Westerveld Donevan2ORCID,Dawod Enad2,Carr-Locke David L.2,Sampath Kartik2,Sharaiha Reem Z.3ORCID,Mahadev Srihari2

Affiliation:

1. MD Program, Weill Cornell Medical College, New York, United States

2. Division of Gastroenterology and Hepatology, NewYork-Presbyterian Weill Cornell Medical Center, New York, United States

3. Division of Gastroenterology and Hepatology, Weill Cornell Medical College, New York, United States

Abstract

Abstract Background and study aims Endoscopic ultrasound-guided gastroenterostomy (EUS-GE) is an emerging procedure that lacks technical standardization with limited adoption beyond expert centers. We surveyed high-volume endosonographers about the technical aspects of EUS-GE to describe how the procedure is currently performed at expert centers and identify targets for standardization. Methods Invitations to complete an electronic survey were distributed to 21 expert EUS practitioners at 19 U.S. centers. Respondents were surveyed about technical aspects of EUS-GE, indications, efficacy, safety, and attitudes toward the procedure. Results All 21 (100%) invited expert endoscopists completed the survey. Nine (42.9%) reported performing >10 EUS-GEs in the last 12 months. About half (47.6%, 10/21) puncture the target loop prior to lumen-apposing metal stent (LAMS) introduction, most often to confirm the loop is jejunum. No respondents reported guidewire placement prior to LAMS introduction. Most (71.4%, 15/21) do not use a guidewire at any time, while 28.6% (6/21) reported wire placement after distal flange deployment to secure the tract during apposition. Eight (38.1%, 8/21) reported at least one major adverse event, most commonly intraperitoneal LAMS deployment (87.5%, 7/8). Factors most often reported as advantageous for EUS-GE over enteral stenting included lack of papilla interference (33.3%, 7/21) and decreased occlusion risk (23.8%, 5/21). Conclusions Significant variation in performance technique for EUS-GE exists among expert US endoscopists, which may hinder widespread adoption and contribute to inconsistencies in reported patient outcomes. The granularity provided by these survey results may identify areas to focus standardization efforts and guide future studies on developing an ideal EUS-GE protocol.

Publisher

Georg Thieme Verlag KG

Subject

Obstetrics and Gynecology

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3