Single-center experience demonstrating low adverse events and high efficacy with self-expandable metal esophageal and biliary stents for pseudocyst and walled off necrosis drainage

Author:

Ortizo Ronald Dungca1,Jalali Farid1,Thieu Daniel1,Yu Allen1,Bucayu Robert1,Paiji Christopher1,Fortinsky Kyle1,Chang Kenneth1,Lee John Gunn1,Samarasena Jason Buddika1

Affiliation:

1. H. H. Chao Comprehensive Digestive Disease Center, University of California, Irvine Medical Center, Orange, California, United States

Abstract

Abstract Background and study aims Lumen-apposing metal stents (LAMS) have been designed as proprietary stents for the management of pseudocysts (PC)/walled off necrosis (WON). There has been concern about adverse events (AEs) with LAMS including bleeding, buried stent syndrome and migration. Prior to LAMS becoming available, fully-covered self-expandable metal esophageal and biliary stents (FCSEMSs) were used off-label for management of PC/WON with many centers demonstrating low rates of AEs. The primary aim of this study was to study the safety and efficacy of FCSEMS for the management of pseudocysts/WON. Patients and methods This was a retrospective review of all endoscopic ultrasound (EUS)-guided placement of FCSEMSs for drainage of PC/WON cases performed at our institution over 4-year period. The primary outcomes studied were technical success, AEs, PC/WON resolution, and salvage surgical/radiologic intervention. Results Technical success achieved in 65 of 65 (100 %) study patients. An AE occurred 0 of 25 patients (0 %) with PC, and in 10 of 40 patients (25 %) with WON: bleeding (3 %), migration (5 %) and stent dysfunction/infection (18 %). There was resolution in 25 of 25 patients (100 %) with a PC and 31 of 40 patients (78 %) with a WON. Salvage therapy by interventional radiology or surgery was performed in nine of 40 patients (22 %). Conclusions This single-center 4-year experience in the pre-LAMS era showed that FCSEMS was safe and effective in all patients with PC and over 75 % of patients with WON. Given the large cost differential between LAMS and FCSEMS and the efficacy and safety shown with FCSEMS, we believe that FCSEMS should still be considered a first-line option for patients with pancreatic fluid collections, particularly in patients with PCs.

Publisher

Georg Thieme Verlag KG

Subject

Gastroenterology,Medicine (miscellaneous)

Reference16 articles.

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3