Radioablation of Upper Abdominal Malignancies by CT-Guided, Interstitial HDR Brachytherapy: A Multivariate Analysis of Catheter Placement Assisted by Ultrasound Imaging

Author:

Damm Robert1,Damm Romy1,Heinze Constanze1,Surov Alexey1,Omari Jazan1,Pech Maciej1,Powerski Maciej1

Affiliation:

1. Klinik für Radiologie und Nuklearmedizin, Universitätsklinikum Magdeburg, Germany

Abstract

Purpose To evaluate the use of ultrasound (US) during catheter placement in interstitial brachytherapy (iBT) of abdominal malignancies as an alternative to computed tomography (CT) fluoroscopy. Materials and Methods Catheter placement for CT-guided iBT was, if US visibility was sufficient, assisted by sonography in 52 consecutive patients with 82 lesions (liver N = 62; kidney N = 16; peritoneum N = 4) of various malignancies. We collected data on lesion visibility, location, depth, size, and dosimetry. Comparison of CT fluoroscopy versus US-assisted catheter placement was performed by Fisher’s exact test for frequencies and U-test for lesion visibility and dosimetric data. Factors predicting the utility of sonography were determined in a lesion-based multivariate regression analysis. A p-value < 0.05 was regarded as statistically significant. Results 150 catheters (1 to 6 per lesion; mean diameter 3.6 ± 2.4 cm) were implanted. CT fluoroscopy was used for 44 catheters, and US was used for 106 catheters. Lesion visibility assessed by 5-point Likert scale was significantly better in US (median 2 vs. 3; p = 0.011) and effective dose was significantly reduced if US guidance was applicable (median 1.75 vs. 8.19 mSv; p = 0.014). In a multivariate regression analysis, we identified increased lesion size and caudal location within the target organ to independently predict the utility of ultrasound in catheter placement for iBT. Conclusion Sonography is a helpful technique to assist CT-guided interstitial brachytherapy of upper abdominal malignancies. Especially for larger lesions localized in the lower liver segments or lower half of the kidney, superior visibility can be expected. As the effective dose of the patient is also reduced, radiation exposure of the medical staff may be indirectly lowered. Key Points:  Citation Format

Publisher

Georg Thieme Verlag KG

Subject

Radiology, Nuclear Medicine and imaging

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3