Measurement of Gastric Emptying Using a 13C-octanoic Acid Breath Test with Wagner-Nelson Analysis and Scintigraphy in Type 2 Diabetes

Author:

Trahair Laurence G1,Nauck Michael A2,Wu Tongzhi13,Stevens Julie E145,Buttfield Madeline D5,Hatzinikolas Seva1,Pham Hung1,Meier Juris J2,Rayner Christopher K16,Horowitz Michael13,Jones Karen L135

Affiliation:

1. Adelaide Medical School and Centre of Research Excellence in Translating Nutritional Science to Good Health, The University of Adelaide, South Australia, Australia

2. Diabetes Center Division, Katholisches Klinikum Bochum, St. Josef-Hospital, Ruhr-University, Bochum, Germany

3. Endocrine and Metabolic Unit, Royal Adelaide Hospital, Adelaide, South Australia, Australia

4. School of Health and Biomedical Sciences, RMIT University, Victoria, Australia

5. Division of Health Sciences, University of South Australia, South Australia, Australia

6. Department of Gastroenterology and Hepatology, Royal Adelaide Hospital, Adelaide, South Australia, Australia

Abstract

Abstract Introduction Breath tests utilising 13C-labelled substrates for the assessment of gastric emptying have been applied widely. Wagner-Nelson analysis is a pharmacokinetic model that can be utilised to generate a gastric emptying curve from the % 13CO2 measured in breath samples. We compared Wagner-Nelson analysis with (i) scintigraphy and (ii) conventional breath test modelling to quantify gastric emptying in type 2 diabetes. Methods Thirteen patients (age 68.1±1.5 years, body mass index 31.0±0.9 kg/m2, HbA1c 6.3±0.2%) consumed a mashed potato meal comprising 65 g powdered potato, 20 g glucose, 250 ml water, an egg yolk labelled with 100 μL 13C-octanoic acid and 20MBq 99mTc-calcium phytate. Scintigraphic data were acquired and breath samples collected for 4 hours after the meal. Gastric emptying curves were derived based on each technique; the 50% emptying time and intragastric retention at 60 min were also calculated. Results With Wagner-Nelson analysis, a Kel=0.60 (the elimination constant) best approximated the scintigraphic gastric emptying curve. There was a relationship between the T50 calculated with scintigraphy and by both Wagner-Nelson Kel=0.60 (r2=0.45, P<0.05) and conventional analysis (r2=0.44, P<0.05). There was no significant difference in the 50% gastric emptying time for scintigraphy (68.5±4.8 min) and Wagner-Nelson Kel=0.60 (71.3±4.5 min), however, the 50% gastric emptying time calculated by conventional analysis was much greater at 164.7±6.0 min (P<0.001). Conclusion In type 2 diabetes, gastric emptying of a mashed potato meal measured using a 13C-octanoic acid breath test analysed with Wagner-Nelson Kel=0.60 closely reflects measurements obtained with scintigraphy, whereas, in absolute terms, the conventional breath test analysis does not.

Funder

Royal Adelaide Hospital

Publisher

Georg Thieme Verlag KG

Subject

Endocrinology,General Medicine,Endocrinology, Diabetes and Metabolism,Internal Medicine

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3