Colon cleansing efficacy and safety with 1 L NER1006 versus 2 L polyethylene glycol + ascorbate: a randomized phase 3 trial

Author:

Bisschops Raf1,Manning Jonathan2,Clayton Lucy3,Ng Kwet Shing Richard3,Álvarez-González Marco4,

Affiliation:

1. KU Leuven, University Hospitals Leuven, Leuven, Belgium

2. Borders General Hospital, NHS Borders, Melrose, United Kingdom

3. Clinical Development, Norgine Ltd, Harefield, United Kingdom

4. Hospital del Mar, Barcelona, Spain

Abstract

Abstract Background Polyethylene glycol (PEG)-based bowel preparations are effective cleansers but many require high-volume intake. This phase 3, randomized, blinded, multicenter, parallel-group, central reader-assessed study assessed the 1 L PEG NER1006 bowel preparation vs. standard 2 L PEG with ascorbate (2LPEG). Methods Patients undergoing colonoscopy were randomized (1:1:1) to receive NER1006, as an evening/morning (N2D) or morning-only (N1D) regimen, or evening/morning 2LPEG. Cleansing was assessed using the Harefield Cleansing Scale (HCS) and the Boston Bowel Preparation Scale (BBPS). Primary end points were overall bowel cleansing success and high-quality cleansing in the right colon. Modified full analysis set (mFAS) and per protocol (PP) analyses were performed. Mean cleansing scores were analyzed post hoc. Results Of 849 randomized patients, efficacy was analyzed in the following patient numbers (mFAS/PP): total n = 822/670; N2D n = 275/220; N1D n = 275/218; 2LPEG n = 272/232. mFAS established noninferiority. PP showed superiority for N2D on overall success (97.3 % vs. 92.2 %; P = 0.014), and for N2D and N1D on right colon high-quality cleansing (N2D 32.3 % vs. 15.9 %, P < 0.001; N1D 34.4 % vs. 15.9 %, P < 0.001) vs. 2LPEG. Using HCS, N2D and N1D attained superior segmental high-quality cleansing (P ≤ 0.003 per segment). N2D showed superior mean segmental HCS scores (P ≤ 0.007 per segment). Both N2D and N1D achieved superior mean overall (P < 0.001 and P = 0.006) and right colon BBPS scores (P < 0.001 and P = 0.013). N2D demonstrated superior right colon polyp detection (P = 0.024). Adherence, tolerability, and safety were comparable between treatments. Conclusions NER1006 is the first low-volume preparation to demonstrate superior colon cleansing efficacy vs. standard 2LPEG with ascorbate, with comparable safety and tolerability. European Clinical Trials Database (EudraCT)2014-002185-78TRIAL REGISTRATION: Multicenter, randomized, parallel group, phase 3 trial 2014-002185-78 at https://eudract.ema.europa.eu/

Publisher

Georg Thieme Verlag KG

Subject

Gastroenterology

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3