Assessment of Tear Meniscus Dimensions Using Anterior Segment Optical Coherence Tomography in Vitamin D Deficiency in a Pediatric Population

Author:

Oren Burak1ORCID,Erboga Çaglar1,Kocaay Funda2,Öztürk Yücel3,Bilak Semsettin4,Kocabas Dilara Ozkoyuncu5ORCID,Balli Haci6,Bilen Abdurrahman1

Affiliation:

1. Ophthalmology, Adiyaman University, Adiyaman, Turkey

2. Public Health, Ankara Medipol University, Ankara, Turkey

3. Ophthalmology, Istanbul Haydarpasa Numune Research and Training Hospital, Istanbul, Turkey

4. Ophthalmology, Private Park Hospital, Adiyaman, Turkey

5. Ophthalmology, TOBB ETU Hospital, Ankara, Turkey

6. Pediatrics, Adiyaman University, Adiyaman, Turkey

Abstract

Abstract Background To investigate of the effect of vitamin D (Vit-D) deficiency on the tear film in children and compare it with that of healthy subjects. Methods This prospective and cross-sectional study comprised 75 eyes of children who had Vit-D deficiency (Group 1) and 85 eyes of age- and gender-matched healthy children (Group 2). The tear-film break-up time (TF-BUT) and Schirmer test values, as well as the Ocular Surface Disease Index (OSDI) scores, were recorded for the participants in all groups. Measurement of the tear meniscus area (TMA) and tear meniscus height (TMH) was performed 2 times in the same day via the use of anterior segment-optical coherence tomography (AS-OCT). Results The mean age of the participants in Group 1 was 12.42 ± 3.40 years, while in Group 2, it was 12.59 ± 2.32 years (p = 0.758). Group 1 comprised 43 females and 32 males, while Group 2 comprised 44 females and 41 males (p = 0.250). The mean TMH, TMA, and Schirmer test values were found to be significantly lower in children with Vit-D deficiency (Group 1) than in healthy children (Group 2), with p < 0.05 for all the values. It was concluded that there was no significant difference in the values for the mean TF-BUT and OSDI scores (p = 0.029 and p = 0.596, respectively). Conclusion The children with Vit-D deficiency exhibited lower TMH, TMA, and Schirmer test values. The alterations that were observed in these parameters were more prominent in the participants who had lower Vit-D levels.

Publisher

Georg Thieme Verlag KG

Subject

Ophthalmology

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3