Body temperature measurement in anesthetized dogs – comparison of nasal, axillary, rectal and esophageal temperature

Author:

Ward Rob12,McMillan Matt32,Gittel Claudia2

Affiliation:

1. Royal (Dick) School of Veterinary Studies, Easter Bush Veterinary Centre, Roslin, United Kingdom

2. Queen’s Veterinary School Hospital, University of Cambridge, Cambridge, United Kingdom

3. The Ralph Veterinary Referral Centre, Marlow, United Kingdom

Abstract

Abstract Objective To evaluate different methods of monitoring body temperature in anesthetized dogs with comparison to core temperature obtained via esophageal probe. Methods Client-owned dogs undergoing general anesthesia for various procedures were included in this observational study. The temperature was taken sequentially every 10 minutes from the rectum, axilla, and nasal cavity with a digital thermistor thermometer, and compared to esophageal core temperature via paired t-tests. Differences from the gold standard esophageal temperature were assessed via Bland-Altman plots and further evaluated for factors like time under anesthesia and presence of Hypo-/Normo- or Hyperthermia. In addition, it was analyzed whether a correction factor for peripheral measurement sites (nasal cavity and axilla) would be applicable in a reliable representation of the body temperature. The level of significance in all tests was set at p<0.05. Results In this study, 95 simultaneous temperature measurements at the 4 different sites were obtained from 30 dogs. Mean difference and limits of agreement from esophageal temperature for the different measurement methods were 0.0±0.72°C for rectal temperature, −1.2±1.42°C for axillary and −1.0±2.02°C for nasal temperature. Axillary and nasal temperatures were not significantly different (p=0.5721 and p=0.9287, respectively) from esophageal temperature with a +1.2°C and +1°C correction factor, respectively. Conclusion and Clinical relevance During perioperative temperature measurement in anesthetized patients, rectal and esophageal measurements can be used interchangeable. However, if these are not available, the use of axillary or nasal sites is only reliable after applying a correction factor.

Publisher

Georg Thieme Verlag KG

Subject

Small Animals

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3