Do Delivery Mode and Anesthesia Management Alter Redox Setting in Neonates?

Author:

Rakić Goran12,Dobrijević Dejan34,Uram-Benka Anna12,Antić Jelena56,Uram-Dubovski Jasminka7,Andrijević Ljiljana3,Drašković Biljana12

Affiliation:

1. Department of Emergency Medicine, University of Novi Sad Medical Faculty, Novi Sad, Serbia

2. Department of Anesthesiology, Institute for Children and Youth Health Care of Vojvodina, Novi Sad, Serbia

3. Department of Biochemistry, University of Novi Sad Medical Faculty, Novi Sad, Serbia

4. Department of Laboratory Diagnostics, Institute for Children and Youth Health Care of Vojvodina, Novi Sad, Serbia

5. Department of Surgery, University of Novi Sad Medical Faculty, Novi Sad, Serbia

6. Department of Surgery, Institute for Children and Youth Health Care of Vojvodina, Novi Sad, Serbia

7. Obstetrics and Gynecology Clinic, Clinical Center of Vojvodina, Novi Sad, Serbia

Abstract

AbstractObjective Fetal-to-neonatal transition is accompanied by oxidative stress. The degree of oxidative damage may depend on several factors, such as delivery type and obstetric anesthesia type. The objective of the study was to determine if the delivery type and obstetric anesthesia type have an impact on oxidative stress levels in newborns.Material and methods A prospective study included 150 newborns divided into three groups: neonates delivered vaginally, via cesarean section in general anesthesia, and via cesarean section in spinal anesthesia. Levels of pH, PaO2, lactate, glutathione peroxidase, and thiobarbituric acid reactive substance were quantified and compared between groups.Results Vaginal delivery was followed by the highest lactate and thiobarbituric acid reactive substance levels and lowest pH, PaO2, and glutathione peroxidase levels. Higher values of thiobarbituric acid reactive substance, PaO2, and glutathione peroxidase and lower pH values were noted in neonates delivered in general anesthesia in comparison to neonates delivered in spinal anesthesia.Conclusions Neonates delivered in general anesthesia were most prone to oxidative stress, while neonates delivered in spinal anesthesia were least affected by reactive oxygen species.

Publisher

Georg Thieme Verlag KG

Subject

Maternity and Midwifery,Obstetrics and Gynecology,Pediatrics, Perinatology and Child Health

Reference21 articles.

1. Comprehensive analysis of oxidative stress markers and antioxidants status in preeclampsia;A Taravati;Taiwan J Obstet Gynecol,2018

2. Antioxidative status and oxidative stress in the fetal circulation at birth: the effects of time of delivery and presence of labor;D Katzer;Early Hum Dev,2015

3. Comparison of oxidative stress markers and serum cortisol between normal labor and selective cesarean section born neonates;R K Nejad;J Clin Diagn Res,2016

4. Oxidative stress, gene expression, and protein changes induced in the human placenta during labor;T Cindrova-Davies;Am J Pathol,2007

5. On the relation of oxidative stress in delivery mode in pregnant women; a toxicological concern;K Vakilian;Toxicol Mech Methods,2009

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3