Diagnostic Accuracy of a Bespoke Multiorgan Ultrasound Approach in Suspected Pulmonary Embolism

Author:

Falster Casper123ORCID,Egholm Gro4ORCID,Wiig Rune2,Poulsen Mikael Kjær4ORCID,Møller Jacob Eifer4ORCID,Posth Stefan5ORCID,Brabrand Mikkel5ORCID,Laursen Christian Borbjerg12ORCID

Affiliation:

1. Department of Respiratory Medicine, Odense University Hospital, Odense, Denmark

2. Odense Respiratory Research Unit (ODIN), Department of Clinical Research, University of Southern Denmark, Odense, Denmark

3. OPEN, Open Patient data Explorative Network, Odense University Hospital, Odense, Denmark

4. Department of Cardiology, Odense University Hospital, Odense, Denmark

5. Department of Emergency Medicine, Odense University Hospital, Odense, Denmark

Abstract

Abstract Purpose The aims of this study were to prospectively assess the diagnostic accuracy of a bespoke multiorgan point-of-care ultrasound approach for suspected pulmonary embolism and evaluate if this model allows reduced referral to further radiation diagnostics while maintaining safety standards. Materials and Methods Patients with suspected pulmonary embolism referred for CT pulmonary angiography or ventilation/perfusion scintigraphy were included as a convenience sample. All patients were subject to blinded ultrasound investigation with cardiac, lung, and deep venous ultrasound. The sensitivity and specificity of applied ultrasound signs and the hypothetical reduction in the need for further diagnostic workup were calculated. Results 75 patients were prospectively enrolled. The Wells score was below 2 in 48 patients, between 2 and 6 in 24 patients, and above 6 in 3 patients. The prevalence of pulmonary embolism was 28%. The most notable ultrasound signs were presence of a deep venous thrombus, at least two hypoechoic pleural-based lesions, the D-sign, the 60/60-sign, and a visible right ventricular thrombus which all had a specificity of 100%. Additionally, a multiorgan ultrasound investigation with no findings compatible with pulmonary embolism yielded a sensitivity of 95.2% (95%CI: 76.2–99.9). CT or scintigraphy could be safely avoided in 70% of cases (95%CI: 63.0–83.1%). Conclusion The findings of our study suggest that implementation of a multiorgan ultrasound assessment in patients with suspected pulmonary embolism may safely reduce the need for CT or scintigraphy by confirming or dismissing the suspicion.

Publisher

Georg Thieme Verlag KG

Subject

Radiology, Nuclear Medicine and imaging

Cited by 2 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3