Effect of a novel endoscope cleaning brush on duodenoscope contamination

Author:

Bruno Marco J.1,Severin Juliëtte A.2,van der Ploeg Koen12ORCID,Haanappel Cynthia P.2,Voor in ’t holt Anne F.2,de Groot Woutrinus2,Bulkmans Adriana J.C.3,Erler Nicole S.45ORCID,Mason-Slingerland Bibi C.G.C.2,Vos Margreet C.2

Affiliation:

1. Department of Gastroenterology and Hepatology, Erasmus MC University Medical Center Rotterdam, Rotterdam, Netherlands

2. Department of Medical Microbiology and Infectious Diseases, Erasmus MC University Medical Center Rotterdam, Rotterdam, Netherlands

3. Quality Assurance and Regulatory Affairs office Medical Technology, Erasmus MC University Medical Center Rotterdam, Rotterdam, Netherlands

4. Department of Biostatistics, Erasmus MC University Medical Center Rotterdam, Rotterdam, Netherlands

5. Department of Epidemiology, Erasmus MC University Medical Center Rotterdam, Rotterdam, Netherlands

Abstract

Abstract Background Current duodenoscope reprocessing protocols are insufficient to prevent contamination and require adaptations to prevent endoscopy-associated infections (EAIs). This study aimed to investigate the effect of a new endoscope cleaning brush on the contamination rate of ready-to-use duodenoscopes. Methods This retrospective before-and-after intervention study collected duodenoscope surveillance culture results from March 2018 to June 2022. Contamination was defined as ≥1 colony-forming unit of a microorganism of gut or oral origin (MGO). In December 2020, an endoscope cleaning brush with a sweeper design was introduced as an intervention in the manual cleaning of duodenoscopes. A logistic mixed-effects model was used to study the effects of this intervention. Results Data were collected from 176 culture sets before the new brush’s introduction and 81 culture sets afterwards. Pre-introduction, culture sets positive with an MGO comprised 45.5% (95%CI 38.3%–52.8%; 80/176), decreasing to 17.3% (95%CI 10.6%–26.9%; 14/81) after implementation of the new brush. Compared with the former brush, duodenoscopes cleaned with the new brush had lower odds of contamination with MGOs (adjusted odds ratio 0.25, 95%CI 0.11–0.58; P=0.001) Conclusions Use of the new brush in manual cleaning reduced contamination with MGOs and is expected to prevent EAIs. These findings should be confirmed in future prospective randomized studies.

Publisher

Georg Thieme Verlag KG

Subject

Gastroenterology

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3