Can Intubation Be Improved with Endotracheal Tubes Marked with a Color Scale? Randomized Controlled Study

Author:

Berazategui Juan P.123,Larcade Ramon P.34,Fernández Ariel L.3,Soria Rose M.3,Castro Adriana A.35,Ávila Aldana S.34,Vain Nestor E.34

Affiliation:

1. Neonatology Unit, Sanatorio Anchorena San Martin, Buenos Aires, Argentina

2. Neonatology Unit, Austral University Hospital, Pilar, Buenos Aires, Argentina

3. Department of Clinical Research - Foundation for Maternal and Child Health, Buenos Aires, Argentina

4. Neonatology Unit – Sanatorio de la Trinidad Palermo and Ramos Mejía, Buenos Aires, Argentina

5. Neonatology Unit, Hospital Evita Lanús, Buenos Aires, Argentina

Abstract

Objective This study aimed to assess if a color scale in the endotracheal tube (ETT) can help operators to correctly select the size and depth of placement of the ETT and decrease the time required to complete the procedure and compared with the usual numeric ETT scale in a mannequin model. Study Design The study was conducted in eight centers. Each size of the ETT was identified with a different color. The experimental ETTs had two different colored areas, one for the mouthpiece and another to identify where the ETT should be taped above the lip (an area of 1 cm. The operators were trained as part of the protocol using an instructional video. Four clinical scenarios requiring endotracheal intubation were designed and randomly assigned. Each operator had to select the size and depth of ETT based on the birth weight (BW), and then had to perform four intubations. Results A total of 108 operators performed 432 intubations. No differences were found in the correct placement and selection of the ETT. Median time (in seconds) required for intubation using numeric versus experimental tube was: for ETT Ø NRP (Neonatal Resuscitation Program) 2.5, 11.5 versus 8 (p < 0.001), ETT Ø 3, 12 versus 10 (p < 0.001), ETT Ø 3.5, 15.5 versus12 (p = 0.003), ETT Ø 4, 12 versus11 (p = 0.019). Conclusion No significant difference was observed in the selection and correct placement of the ETT. However, the intubation time was significantly shorter using the experimental ETT. This device could improve the effectiveness of intubation by reducing the time needed to properly place the ETT at mid trachea. Key Points

Funder

Fundación para la Salud Materno Infantil

Publisher

Georg Thieme Verlag KG

Subject

Obstetrics and Gynecology,Pediatrics, Perinatology and Child Health

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3