Diagnostic Performance of a Particle Gel Immunoassay in Vaccine-Induced Immune Thrombotic Thrombocytopenia

Author:

Uzun Günalp1,Althaus Karina12,Hammer Stefanie1,Wanner Yvonne1,Nowak-Harnau Stefanie1,Enkel Sigrid1,Bakchoul Tamam12

Affiliation:

1. Centre for Clinical Transfusion Medicine, University Hospital of Tuebingen, Tuebingen, Germany

2. Institute for Clinical and Experimental Transfusion Medicine, Medical Faculty of Tuebingen, University Hospital of Tuebingen, Tuebingen, Germany

Abstract

AbstractVaccine-induced immune thrombotic thrombocytopenia (VITT) is a rare but serious complication of adenoviral vector-based COVID-19 vaccines. Similar to heparin-induced thrombocytopenia (HIT), antibodies reacting to platelet factor 4 (PF4) are responsible for platelet activation in VITT. The diagnosis of VITT includes the detection of anti-PF4 antibodies. Particle gel immunoassay (PaGIA) is one of the rapid immunoassays that is commonly used in the diagnosis of HIT to detect anti-PF4 antibodies. The aim of this study was to investigate the diagnostic performance of PaGIA in patients suspected of VITT. In this retrospective, single-center study, the correlation between PaGIA, enzyme immunoassay (EIA), and modified heparin-induced platelet aggregation assay (HIPA) in patients with findings suggestive of VITT was investigated. A commercially available PF4 rapid immunoassay (ID PaGIA H/PF4, Bio-Rad-DiaMed GmbH, Switzerland) and an anti-PF4/heparin EIA (ZYMUTEST HIA IgG, Hyphen Biomed) were used according to manufacturer's instructions. Modified HIPA was accepted as the gold standard test. Between March 8 and November 19, 2021, a total of 34 samples from clinically well-characterized patients (14 males, 20 females, mean age: 48.2 ± 18.2 years) were analyzed with PaGIA, EIA, and modified HIPA. VITT was diagnosed in 15 patients. Sensitivity and specificity of PaGIA were 54 and 67%, respectively. Anti-PF4/heparin optical density values were not significantly different between PaGIA positive and negative samples (p = 0.586). The sensitivity and specificity of EIA, on the other hand, were 87 and 100%, respectively. In conclusion, PaGIA is not reliable in the diagnosis of VITT because of its low sensitivity and specificity.

Funder

German Research Foundation

Herzstiftung

Publisher

Georg Thieme Verlag KG

Subject

Hematology

Cited by 3 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3