Role of Ultrahigh Frequency Ultrasound in Evaluating Experimental Flaps

Author:

Morarasu Stefan12ORCID,Ghetu Nicolae13,Coman Corneliu George123,Morarasu Bianca Codrina1,Boicu Daniel1,Spiridon Irene Alexandra4,Gardikiotis Ioannis12,Danciu Mihai4,Pieptu Dragos13ORCID

Affiliation:

1. Center of Simulation and Training in Surgery, Grigore T. Popa University of Medicine and Pharmacy, Iasi, Romania

2. Advanced Center for Research and Development in Experimental Medicine, Grigore T. Popa University of Medicine and Pharmacy, Iasi, Romania

3. Department of Plastic and Reconstructive Surgery, Grigore T. Popa University of Medicine and Pharmacy, Iasi, Romania

4. Department of Pathology, Grigore T. Popa University of Medicine and Pharmacy, Iasi, Romania

Abstract

Abstract Background Experimental flap follow-up needs faster, safer, and less invasive techniques that can be easily correlated to clinical procedures. For this reason, we aimed to test the role of ultrahigh frequency ultrasound in follow-up of flap viability. Further on, we aimed to analyze if the chimeric groin flap can be mobilized in a sandwiched position without affecting its vascular supply by twisting its pedicle. Methods A total of 12 male Wistar rats, split into three groups, were used. Group A (n = 4) had the chimeric groin flap repositioned in a sandwich position on the anterior abdominal wall and underwent ultrahigh frequency ultrasound follow-up at days 10 and 14. Group B (n = 4) also had the flaps sandwiched, however, at day 14 the vascularity of flaps was proven by infusion of nontargeted ultrasound contrast agents, after which flaps were sent for histological analysis. Group C (C1 n = 2, C2 n = 2) was the control group. In C1 the chimeric groin flap was harvested and sent for histology on day 0, acting as a histological benchmark of flap viability, and in C2 the chimeric groin flap was re-sutured in its anatomical position and after 14 days, flaps were harvested and sent for histological analysis, acting as a direct control for Group B. Results Ultrasound showed constant vascular flow in both adipose and skin flaps in the sandwiched position. Microbubble study showed diffuse perfusion within flaps. Ultrasound measurements of flow velocity, flap volume, and percentage of vascularity showed a decrease in flap volume and increase in vascularity over 14 days. Histology showed similar viability in both groups. Conclusion Ultrahigh frequency ultrasound may be a valuable tool for postoperative flap assessment, while the chimeric flap can be moved freely in a sandwich position making it suitable for adding tissue substitutes within its components.

Publisher

Georg Thieme Verlag KG

Subject

Surgery

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3