Influence of Interlocking Horizontal Mattress Epitendinous Suture Placement on Tendinous Biomechanical Properties in a Canine Common Calcaneal Laceration Model

Author:

Cocca Christina J.1,Duffy Daniel J.2ORCID,Kersh Mariana E.3,Moore George E.4

Affiliation:

1. Department of Veterinary Clinical Medicine, College of Veterinary Medicine, University of Illinois, Urbana, Illinois, United States

2. Department of Clinical Sciences, College of Veterinary Medicine, North Carolina State University, Raleigh, North Carolina, United States

3. Department of Mechanical Science and Engineering, University of Illinois, Urbana, Illinois, United States

4. Department of Veterinary Administration, College of Veterinary Medicine, Purdue University, West Lafayette, Indiana, United States

Abstract

Abstract Objective This article evaluates the effect of an interlocking horizontal mattress epitendinous suture (IHMES) in addition to a three-loop pulley (3LP) core suture for canine tendon repair. Study Design Twenty-eight cadaveric common calcaneal tendons were randomized, sharply transected and repaired with either a 3LP or 3LP + IHMES. Tensile loads required to create a 1- and 3-mm gap, yield, peak and failure loads, and mode of failure were analysed. Significance was set at p < 0.05. Results Mean ± standard deviation yield and failure force for 3LP + IHMES was 178.0 ± 45.3 N and 242.1 ± 47.8 N, respectively, which was significantly greater compared with 3LP alone, 97.9 ± 36.2 N and 119.3 ± 35.6 N (p < 0.0001). Occurrence of 3-mm gap formation was significantly less in the 3LP + IHMES group (p < 0.013). Mode of failure was significantly different between the groups (p < 0.001) with 3LP + IMHES patterns failing by suture breakage (13/14) compared with suture pull-through in the 3LP (11/14). Conclusion Addition of an epitendinous suture pattern significantly reduced gap formation between tendon ends and significantly increased loads at yield (1.8 × ), peak (2.0 × ) and failure (2.0 × ) force of repairs. Use of an epitendinous suture should be considered to significantly increase biomechanical strength of repairs; however, further in vivo testing is necessary to evaluate its effect on tendinous blood supply.

Publisher

Georg Thieme Verlag KG

Subject

General Veterinary,Animal Science and Zoology

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3