To Evaluate the Effect of Water Temperature and Duration of Immersion on the Marginal Accuracy and Microhardness of Provisional Restoration: An In Vitro Study

Author:

Verma Sanjan1,Kalra Tarun1,Kumar Manjit1,Bansal Ajay1,Batra Ritu2,Avasthi Abhishek1

Affiliation:

1. Department of Prosthodontics, Bhojia Dental College and Hospital, Himachal Pradesh, India

2. Department of Prosthodontics, JCD Dental College and Hospital Sirsa, Haryana, India

Abstract

Abstract Introduction Provisional restoration is a critical component of fixed prosthodontics treatment, which must satisfy many inter-relative factors such as biological, mechanical, and esthetic. These restorations should have accurate marginal adaptation and optimum strength to maintain functional demands. The present “in vitro” study was conducted to evaluate the effect of water temperature and duration of immersion, on the marginal adaptation and microhardness of four different commercially available provisional restorative materials. Materials and Methods The 240 specimens were then seated on the stainless-steel die which simulated the prepared tooth, and evaluated for the marginal gap for four different provisional restorative materials and divided into four different groups A, B, C, and D. Each group was further divided into six subgroups according to temperature of water and time of immersion. In each group the samples were immersed in water at 20, 30, and 40 degrees, respectively for 5 and 10-minutes duration. Four different temporary restorative materials for crown fabrication were loaded each time to make temporary crowns. Results Each sample was placed under travelling stereoscopic microscope (20× magnification) and photographed. Results for each surface were obtained, and the average of three surfaces was calculated. Knoop hardness was measured using a microhardness tester. The study was subjected to statistical analysis, to know the statistical significance, of the effect of difference in time and temperature changes at the time of final polymerization on surface microhardness and marginal integrity of four different provisional restorative materials. Discussion The mean marginal discrepancies of bis-GMA (group B) at 20, 30, and 40°C for 5 and 10 minutes in water were smaller than the results of other groups. Microhardness evaluation showed that the poly ethyl methacrylate (PEMA) type resin exhibited significantly lower microhardness than the bis-acryl resin composites (Protemp 4 and Systemp.c&b) at both time and temperature intervals. Conclusion The bis-acryl composites material has the least marginal discrepancy in comparison with PEMA and polymethyl methacrylate (PMMA). The bis-acryl composites materials exhibit superior surface microhardness followed by PEMA and PMMA.

Publisher

Georg Thieme Verlag KG

Subject

General Medicine

Reference16 articles.

1. Marginal integrity of provisional resin restoration materials: a review of the literature;V Rakhshan;Saudi J Dent Res,2015

2. An invitro evaluation of flexural strength of direct and indirect provisionalization materials;S Dagar;J Indian Prosthodont Soc,2005

3. The provisional fixed partial denture;D R Federick;J Prosthet Dent,1975

4. In-office provisional restorative materials for fixed prosthodontics;H E Strassler;Inside Dentistry,2009

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献