Mechanical Alignment in Knee Replacement Homogenizes Postoperative Coronal Hip–Knee–Ankle Angle in Varus Knees: A Navigation-Based Study

Author:

Larrainzar-Garijo Ricardo12ORCID,Molanes-Lopez Elisa M.3,Murillo-Vizuete David1,Garcia-Bogalo Raul1,Escobar-Anton David1,Lopez-Rodriguez Jesus1,Diez-Fernandez Angel1,Corella-Montoya Fernando12

Affiliation:

1. Department of Orthopadic and Trauma, Hospital Universitario Infanta Leonor, Madrid, Spain

2. Departamento Cirugía, Facultad de Medicina, Universidad Complutense, Madrid, Spain

3. Departamento de Estadística e Investigación Operativa, Unidad Departamental de Bioestadística, Facultad de Medicina, Universidad Complutense, Madrid Spain

Abstract

AbstractAfter knee replacement, postoperative lower limb alignment is influenced by the geometry of the prosthesis position and surrounding soft tissue that contributes to the hip–knee–ankle (HKA) angle. The purpose of this study is to determine the dynamic coronal HKA angle after mechanical alignment in total knee replacement using computer navigation. We conducted a pre–post design study of 71 patients with varus osteoarthritic knees on which total knee arthroplasty was performed. The HKA was measured before and at the end of the surgical procedure with the patient in the supine position using a navigation system at 30, 60, and 90 degrees of knee flexion. Postoperative implant position and flexion and extension gaps were assessed. HKA was clustered in three preoperative dynamic patterns (PDPs; Varus-Neutral, Varus-Valgus, and Varus-Varus). There were statistically significant differences in the dynamic coronal HKA between the preoperative and postoperative statuses after mechanically aligned knee replacement (with p < 0.0001) Before the surgical procedure, statistically significant differences were found between patterns at any angle of flexion confirming a well-differentiated preoperative dynamic behavior between the three groups. Postoperatively, 98.6% (71 out of 72) of the knees were within ± 3 degrees of the HKA at full extension. Fifty-eight knees (80.6%) were assessed to a “within-range” postoperative dynamic alignment at any grade of flexion considered. There are differences between the preoperative and postoperative status of the dynamic coronal HKA angle after mechanically aligned knee replacement. We proposed that an excellent dynamic HKA alignment is achieved not only at full extension within the range of 0 ± 3 degrees but also when this alignment is maintained at 30, 60, and 90 degrees.

Publisher

Georg Thieme Verlag KG

Subject

Orthopedics and Sports Medicine,Surgery

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3