Does the 45 mm Size Cutoff for Ascending Aortic Replacement Predict Better Early Outcomes in Bicuspid Aortic Valve?

Author:

Li Yi-Jia1,Ma Wei-Guo2ORCID,Qi Yue3,Zhu Jun-Ming2,Yang Ya1,Sun Li-Zhong2

Affiliation:

1. Department of Echocardiography, Beijing Anzhen Hospital, Capital Medical University, and Beijing Institute of Heart Lung and Blood Vessel Diseases, Beijing, China

2. Department of Cardiovascular Surgery, Beijing Anzhen Hospital, Capital Medical University, and Beijing Institute of Heart Lung and Blood Vessel Diseases, Beijing, China

3. Department of Epidemiology, Beijing Anzhen Hospital, Capital Medical University, and Beijing Institute of Heart Lung and Blood Vessel Diseases, Beijing, China

Abstract

Abstract Background The aim of this study is to test if the newly proposed 45 mm size criterion for ascending aortic replacement (AAR) in bicuspid aortic valve (BAV) patients undergoing aortic valve replacement (AVR) is predictive of improved early outcomes. Methods Data of 306 BAV patients with an aortic diameter of ≥45 mm undergoing AVR alone or with AAR were retrospectively analyzed. Patients were divided into groups of AVR + AAR (n = 220) and AVR only (n = 86) based on if surgery was performed according to the 45 mm criterion. End point was early adverse events, including 30-day and in-hospital mortality, cardiac events, acute renal failure, stroke, and reoperation for bleeding. Cox regression was used to assess if conformance to 45 mm criterion could predict fewer early adverse events. Results AVR + AAR group had significantly higher postoperative left ventricular ejection fraction (LVEF) (0.59 ± 0.09 vs. 0.55 ± 0.11, p = 0.006) and longer cardiopulmonary bypass (CPB) time (128 vs. 111 minutes, p = 0.002). Early adverse events occurred in 45 patients (14.7%), which was more prevalent in the AVR-only group (22.1% vs. 11.8%, p = 0.020). Conformance to the 45 mm criterion predicted lower rate of early adverse events (hazard ratio [HR]: 0.53, 95% confidence interval [CI]: 0.28–0.98, p = 0.042). After adjustment for gender, age, AAo diameter, sinuses of Valsalva diameter, preoperative LVEF, Sievers subtypes, BAV valvulopathy, and CPB and cross-clamp times, conformance to the 45 mm size criterion still predicted lower incidence of early adverse events (HR: 0.37, 95% CI: 0.15–0.90, p = 0.028). Conclusions This study shows that conformance to 45 mm size cutoff for preemptive AAR during aortic valve replacement in patients with BAV was not associated with increased risk for adverse events and may improve early surgical outcomes.

Publisher

Georg Thieme Verlag KG

Subject

Cardiology and Cardiovascular Medicine,Pulmonary and Respiratory Medicine,Surgery

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3