Abstract

Abstract Background The volar scaphoid plate from Medartis (Medartis AG, Austrasse, Basel, Switzerland) is a variable angle titanium locking plate, preformed for the volar aspect of the scaphoid. It does not have compressive capability, and may act as a bridging device. It may provide an advantage over a compression screw where the pathoanatomy is less favorable to such a device with increased rotational stability. It may act as a buttress plate for correction of humpback deformity for example. It has been used in nonunions and with vascularized grafts. Questions Our study aims to assess the results of our patients with scaphoid nonunion treated with scaphoid volar plating over a larger number of patients. We aim to identify techniques to increase the success of plating. Methods Patients from our cohort were retrospectively reviewed. Operations were performed by three hand fellowship trained surgeons and in two centers. Inclusion involved a scaphoid plate procedure for a nonunion of the scaphoid with a minimum of 6 months of follow-up. Exclusions were those who had less than 6 months of follow-up. Data included demographics, patient-rated wrist evaluation (PRWE), a quick disabilities of the arm, shoulder, and hand (qDASH), visual analogue score, and range and grip. Radiology was reviewed. Results Thirty-two eligible patients were assessed. The mean age was 25 years (range 13–46), 2 were female and 15 were smokers. Mean follow-up postsurgery was 18 months. Twenty-nine of 32 patients united (90.6%) on computed tomography scan. Clinical assessment was performed in the 25 patients. The mean qDASH score was 12.5 (range 0–42) and mean PRWE was 11 (range 0–54). The mean arc of motion was 115 degrees. The mean grip strength was 39 kg compared with 41 kg on the nonoperated side. Conclusion We postulate that the plate acts like an internal bridging device, acting over a small distance, and inherent stability of the construct with structural graft and accurate reduction prior to plating is advantageous. Potential problems include plate impingement on the volar lip of the radius, particularly when trying to plate more proximal fractures. Ideally, it is utilized for mid to distal waist fractures.

Publisher

Georg Thieme Verlag KG

Subject

Orthopedics and Sports Medicine,Surgery

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3