Abstract

Abstract Introduction One of the most seen neurosurgical complications is the ventriculoperitoneal (VP) shunt failure. The cause can be often due to peritoneal malabsorption of cerebrospinal fluid. The next safer alternative is to place a ventriculoatrial (VA) shunt. Various methods of access to the right atrium had been described. The percutaneous method of insertion of distal catheter using Seldinger technique is a safer alternative to open method. We describe the percutaneous insertion of distal catheter using Seldinger technique, modifications in the method, and specific tools required for the insertion. Clinical History The patient is a 22-year-old male who is a known case of tubercular meningitis with recurrent failure of VP shunt due to malabsorption at peritoneal end of catheter. During the last hospital visit, he presented with altered sensorium and computed tomography scan brain showed ventriculomegaly. He was planned for VA shunt placement. Surgical Technique The insertion of ventricular end of the catheter is similar to any other shunt placement. The internal jugular vein (IJV) was punctured using introducer needle and guide wire was placed in the IJV at the level of T6-T7 and the serial dilators passed on the guide wire for creating a track for passage of shunt catheter. The shunt catheter was passed over the guide wire to the desired vertebral level and distal shunt catheter is connected proximally to the shunt catheter in the neck. Conclusion The percutaneous insertion of distal catheter with serial dilators using Seldinger technique is a safe and effective method for VA shunt placement.

Publisher

Georg Thieme Verlag KG

Subject

Materials Chemistry

Reference8 articles.

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3